This comparison covers 2 official alert references, including radio-controlled toy car with remote control., published from 2007-10-12 to 2007-10-12. The recorded risks raise separate evidence questions about insulation, labels/instructions, plug interfaces. Compare the product features and dated findings below before scoping an investigation. These historical observations do not determine your product’s compliance or a market failure rate.
Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.
Dated official observations
Compare the product features and reported failure mechanism
The source wording below describes the reported case at that time. Read each complete report before using it in an investigation.
Radio-controlled toy car with remote control. · 1031/07
Report published 2007-10-12 · notifying country Hungary · reported origin People's Republic of China
Reported product description
The package of the product contains a plastic toy car (scale 1:14) with a control frequency of 27 MHz, operated by batteries, a battery charger (HENGXIN input: AC 110-240V;50/60 Hz; output: DC 4,8V 200mA Class II), a remote control (“SUPER SPEED R/C 27 MHz 9V”), battery ( “4,8V 700mAh MADE IN CHINA”), and a dry battery of 9V 6F22. [1]
Reported risk explanation
The product poses a risk of electric shock because:- the plug of the battery charger is non-standardized, therefore the live pins are accessible when connecting to the power supply,- the cover of the battery charger can be removed without using a tool, - the insulation of the wiring is not sufficient (flashover occurred),- certain safety instructions of the battery charger and warnings are missing. The product does not comply with the Low Voltage Directive and relevant European standards EN-60335 and EN-50088. [1]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authority. Date of entry into force: Unknown [1]
Radio-controlled toy car with remote control. · 1032/07
Report published 2007-10-12 · notifying country Hungary · reported origin People's Republic of China
Reported product description
The package of the product contains a plastic toy car (scale 1:32)with a control frequency of 27 MHz, (number plate on the product: NO.666-20), operated by batteries, a battery charger (HENGXIN input: AC 110-240V;50/60 Hz; output: DC 4,8V 200mA Class II), a remote control (“SUPER SPEED R/C 27 MHz 9V”), battery ( “4,8V 700mAh MADE IN CHINA”), and a dry battery of 9V 6F22. [2]
Reported risk explanation
The product poses a risk of electric shock because:- the plug of the battery charger is non-standardized, therefore the live pins are accessible when connecting to the power supply,- the cover of the battery charger can be removed without using a tool, - the insulation of the wiring is not sufficient (flashover occurred), - certain safety instructions of the battery charger and warnings are missing. The product does not comply with the Low Voltage Directive and relevant European standards EN-60335 and EN-50088. [2]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authority. Date of entry into force: Unknown [2]
2 distinct official alert references, published between 2007-10-12 and 2007-10-12. Counts describe the acquired reports, with no market denominator.
Report year
Recorded alerts
2007
2
Recorded risk labels within this evidence task
Label combinations are source facts within one comparison; they do not create separate guides with identical preparation tasks.
Electric shock: 2 recorded references
Source selection, exclusions and calculation method
Filter the acquired, completely parsed English weekly XML releases. Deduplicate official alert references. Group by product category and the complete set of conditional evidence-question topics supported by actual risk text. Risk-label combinations remain recorded cohort facets and do not create buyer intents. Brand, product name, model, origin, notifying country, measurement-only changes and different wording of the same questions do not create intents. Unrecognized mechanisms stay internal for enrichment. Count report years and notifying countries deterministically. Display at most eight newest descriptions with at least 40 characters after whitespace normalization, nonempty reported measures and distinct casefolded descriptions; break date ties by official identifier. All cohort records count even if their description is shorter or not displayed. This is not a representative sample. Counts concern this acquired corpus only.
One acquired version per official public alert reference. Display at most eight newest distinct product descriptions whose normalized whitespace-collapsed text contains at least 40 characters and has nonempty reported measures; ties sort by official identifier. The complete cohort includes shorter descriptions. This is an explicit display selection, not a representative sample.
2 distinct descriptions displayed; 0 cohort records not displayed. Missing fields: {}.
These are selected, dated enforcement observations in the acquired weekly reports, not a random market sample, market-wide failure rate, proof of current product status, or a determination about your product. Notification country is not a complete sales-market or jurisdiction-coverage field. A quoted legal/standard reference is the report’s statement, not independently verified current law or a mandatory test panel.
Calculation safety-gate-evidence-comparison-10; units recorded alerts; no incidence denominator.
Turn the reported failure mechanism into a scoped investigation
Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.
Power-supply insulation boundaries — what evidence do we have?
If your product uses a mains supply or adapter, identify the actual power-supply architecture, insulation boundaries and accessible parts. Ask a qualified specialist which design evidence and investigation would address the reported shock mechanism for this configuration. No medical-device standard or pass/fail limit is selected from this alert.
Useful evidence: Schematics, adapter/component specifications, ratings, insulation/protection design and configuration-specific existing test evidence.
Plug, socket and connector interfaces — what evidence do we have?
Identify the exact plug/socket or connector configuration, intended country interface and any adapter supplied. Document the interface dimensions, accessible parts and assembly controls for specialist review against current applicable requirements. Do not assume a reported interface failure applies to every configuration.
Labels, instructions and actual use — what evidence do we have?
Capture the exact label/instruction revision and destination/use context. Compare the information gap described in the report with your own product and current sector requirements, keeping a reported defect separate from a universal wording obligation.
Useful evidence: Current labels/instructions, revision and market/translation records, use/risk information and reviewed applicable requirements.
Can we trace the affected component, formula or design revision across our supplied products?
Compare the reported descriptions with your own identifiers and change records. Treat missing or “Unknown” source fields as unresolved; they do not establish that no action was needed.
Useful evidence: Product identifiers, revision history, supplier/batch traceability and market/operator records.
Who would own an evidence review and any resulting corrective-action decision?
Read the reported measures as historical observations. Establish your own operator roles, sector-specific rules, decision owner and communication responsibilities before adopting another case’s response.
Conditional: Product-risk evidence and operator-role review — Compare the recorded product features and failure mechanism with your product. Confirm the applicable product regime, deciding evidence, operator responsibilities and justified next steps. This does not assume that GPSR or a representative appointment applies to every alert category.
Questions for providers
Which specific product features and reported risk mechanism make these cases relevant or irrelevant to our product?
What current legal, standards or scientific sources support your proposed investigation criteria, and what cannot be concluded from these dated alerts?
Which existing evidence can answer the risk question, what additional work is justified, and who owns any resulting corrective-action decision?
Sources and data dates
Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.