This comparison covers 3 official alert references, including table lamp, fluorescent table lamp - eurolite / jupik, published from 2009-01-30 to 2021-05-14. The recorded risks raise separate evidence questions about plug interfaces, stability/load. Compare the product features and dated findings below before scoping an investigation. These historical observations do not determine your product’s compliance or a market failure rate.
Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.
Dated official observations
Compare the product features and reported failure mechanism
The source wording below describes the reported case at that time. Read each complete report before using it in an investigation.
Table lamp · A12/00627/21
Report published 2021-05-14 · notifying country Hungary · reported origin People's Republic of China
Reported product description
Lava lamp with rising and sinking coloured balls in liquid. Size: Ø110 mm x 420 mm. [1]
Reported risk explanation
The lamp is attractive to children and it is not equipped with a transformer or converter. It is instable and may easily overturn. The live parts of the socket contact may become accessible. The bulb can become very hot (168.6 °C) and be touched freely. Consequently the children may suffer burns or electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598. [1]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: ManufacturerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 27/01/2021 [1]
Report published 2021-05-14 · notifying country Hungary · reported origin People's Republic of China
Reported product description
Rainbow coloured, metal decorative lava lamp with glittering particles flowing in liquid. [2]
Reported risk explanation
The lamp is attractive to children and it is not equipped with a transformer or converter. It is instable and may easily overturn. The live parts of the socket contact may become accessible. The bulb can become very hot (175.5 °C) and be touched freely. Consequently the children may suffer burns or electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598. [2]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: ManufacturerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 28/01/2021Type of economic operator to whom the measure(s) were ordered: ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: 28/01/2021 [2]
Report published 2009-01-30 · notifying country Czechia · reported origin People's Republic of China
Reported product description
A table lamp (classified protection II), with casing IP20, basic technical data: 230V, 50 Hz, tube DZ 9W with socket G23. Multilingual instructions, packed in a cardboard box approx. 40x10x5 cm. [3]
Reported risk explanation
The product poses a risk of electric shock because: - the lamp is unstable and can tip over, - the plastic casing does not withstand heat; - due to a fault in the socket of the fluorescent lamp the temperature of the base may increase causing distortion of parts, - the tube socket does not withstand high temperatures, - the tube socket does not comply with fire resistance requirements. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598. [3]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban ordered by the authorities.Date of entry into force: Unknown [3]
3 distinct official alert references, published between 2009-01-30 and 2021-05-14. Counts describe the acquired reports, with no market denominator.
Report year
Recorded alerts
2009
1
2021
2
Recorded risk labels within this evidence task
Label combinations are source facts within one comparison; they do not create separate guides with identical preparation tasks.
Burns, Electric shock: 2 recorded references
Electric shock: 1 recorded references
Source selection, exclusions and calculation method
Filter the acquired, completely parsed English weekly XML releases. Deduplicate official alert references. Group by product category and the complete set of conditional evidence-question topics supported by actual risk text. Risk-label combinations remain recorded cohort facets and do not create buyer intents. Brand, product name, model, origin, notifying country, measurement-only changes and different wording of the same questions do not create intents. Unrecognized mechanisms stay internal for enrichment. Count report years and notifying countries deterministically. Display at most eight newest descriptions with at least 40 characters after whitespace normalization, nonempty reported measures and distinct casefolded descriptions; break date ties by official identifier. All cohort records count even if their description is shorter or not displayed. This is not a representative sample. Counts concern this acquired corpus only.
One acquired version per official public alert reference. Display at most eight newest distinct product descriptions whose normalized whitespace-collapsed text contains at least 40 characters and has nonempty reported measures; ties sort by official identifier. The complete cohort includes shorter descriptions. This is an explicit display selection, not a representative sample.
3 distinct descriptions displayed; 0 cohort records not displayed. Missing fields: {}.
These are selected, dated enforcement observations in the acquired weekly reports, not a random market sample, market-wide failure rate, proof of current product status, or a determination about your product. Notification country is not a complete sales-market or jurisdiction-coverage field. A quoted legal/standard reference is the report’s statement, not independently verified current law or a mandatory test panel.
Calculation safety-gate-evidence-comparison-10; units recorded alerts; no incidence denominator.
Turn the reported failure mechanism into a scoped investigation
Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.
Plug, socket and connector interfaces — what evidence do we have?
Identify the exact plug/socket or connector configuration, intended country interface and any adapter supplied. Document the interface dimensions, accessible parts and assembly controls for specialist review against current applicable requirements. Do not assume a reported interface failure applies to every configuration.
Stability and load-bearing use — what evidence do we have?
Identify the intended loads, support/attachment design, adjustment positions and use surface. Compare the reported collapse or instability mechanism with the actual configuration and agree a supported investigation rather than copying another case’s response.
Can we trace the affected component, formula or design revision across our supplied products?
Compare the reported descriptions with your own identifiers and change records. Treat missing or “Unknown” source fields as unresolved; they do not establish that no action was needed.
Useful evidence: Product identifiers, revision history, supplier/batch traceability and market/operator records.
Who would own an evidence review and any resulting corrective-action decision?
Read the reported measures as historical observations. Establish your own operator roles, sector-specific rules, decision owner and communication responsibilities before adopting another case’s response.
Conditional: Product-risk evidence and operator-role review — Compare the recorded product features and failure mechanism with your product. Confirm the applicable product regime, deciding evidence, operator responsibilities and justified next steps. This does not assume that GPSR or a representative appointment applies to every alert category.
Questions for providers
Which specific product features and reported risk mechanism make these cases relevant or irrelevant to our product?
What current legal, standards or scientific sources support your proposed investigation criteria, and what cannot be concluded from these dated alerts?
Which existing evidence can answer the risk question, what additional work is justified, and who owns any resulting corrective-action decision?
Sources and data dates