Reported risk evidence comparison

Electrical appliances and equipment: plasticizers — reported risk evidence

The acquired cohort contains 26 official alert references published from 2021-12-17 to 2026-05-01. This page compares 8 selected, distinct product descriptions, including hdmi cable, waffle maker, battery charger. The other 18 records still contribute to the cohort counts but are not displayed: descriptions may repeat, lack the display inputs, or fall outside the eight-description display limit. The recorded risks raise separate evidence questions about plasticizers. Compare the product features and dated findings below before scoping an investigation. These historical observations do not determine your product’s compliance or a market failure rate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Dated official observations

Compare the product features and reported failure mechanism

The source wording below describes the reported case at that time. Read each complete report before using it in an investigation.

HDMI cable · SR/01283/26

Report published 2026-05-01 · notifying country Sweden · reported origin Unknown

Reported product description
High speed HDMI cable with ethernet. Product sold online, in particular via www.atea.se. [1]
Reported risk explanation
The plastic material of the cable has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 10 % by weight).This phthalate poses a risk to human health and the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive). [1]
Reported measures, verbatim
Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator taking notified measure(s): DistributorCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 26/09/2025Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 14/10/2025 [1]

Read the official alert ↗

Waffle maker · SR/04497/25

Report published 2025-12-26 · notifying country Slovenia · reported origin People's Republic of China

Reported product description
Waffle maker in the shape of a heart. Product sold online, in particular via www.vitapur.si. [2]
Reported risk explanation
The plastic of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured values up to 1.6% by weight). This phthalate may harm the health by causing possible damage to the reproductive system. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive). [2]
Reported measures, verbatim
Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 17/11/2025Type of economic operator taking notified measure(s): OtherCategory of measure(s): Removal of this product listing by the online marketplaceDate of entry into force: 17/11/2025 [2]

Read the official alert ↗

Battery charger · SR/03714/25

Report published 2025-10-24 · notifying country Luxembourg · reported origin Unknown

Reported product description
Fully automatic battery charger with dimensions of 188 x 72 x 44 mm. [3]
Reported risk explanation
The plastic material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 14.4% by weight). This phthalate may harm the health by causing possible damage to the reproductive system. The product does not comply with the REACH Regulation. [3]
Reported measures, verbatim
Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: Unknown [3]

Read the official alert ↗

Children's camera · SR/01073/25

Report published 2025-03-28 · notifying country Sweden · reported origin People's Republic of China

Reported product description
Small blue digital camera with a USB-cable. Product sold online in particular via www.dhgate.com. [4]
Reported risk explanation
The plastic material of the cable has excessive concentrations of bis(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DBP), lead and short chain chlorinated paraffins (SCCPs) (measured values up to 0.42%, 1.6%, 0.34% and 1.7% by weight, respectively). DEHP and DBP pose a risk to human health and the environment. Lead poses a risk to the environment. SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive) nor with the Persistent Organic Pollutants (POP) Regulation. [4]
Reported measures, verbatim
Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Removal of this product listing by the online marketplace/webshopDate of entry into force: 09/03/2025 [4]

Read the official alert ↗

USB adaptor · SR/00523/25

Report published 2025-02-07 · notifying country Sweden · reported origin Unknown

Reported product description
90x40x5 millimetre adaptor with dual USB 3.0/A female contacts. Blue plastic coating. [5]
Reported risk explanation
The plastic material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) and short chain chlorinated paraffins (SCCPs) (measured values: 4.32% and 5.3% by weight, respectively).DEHP may harm the health by causing possible damage to the reproductive system. SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive) nor with the Persistent Organic Pollutants (POP) Regulation. [5]
Reported measures, verbatim
Type of economic operator taking notified measure(s): RetailerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 17/07/2024 [5]

Read the official alert ↗

Insect trap · A12/03031/24

Report published 2024-11-01 · notifying country Slovakia · reported origin People's Republic of China

Reported product description
Mosquito and flying insects trap in white colour, which includes a permanently connected USB power cable. [6]
Reported risk explanation
The plastic material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) (measured values: 7.11% and 6.68% by weight, respectively). These phthalates may pose a risk to human health and the environment. The product does not comply with the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive). [6]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Warning consumers of the risksDate of entry into force: 24/09/2024Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 24/09/2024Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Recall of the product from end usersDate of entry into force: 24/09/2024 [6]

Read the official alert ↗

LED light · A12/02319/24

Report published 2024-08-23 · notifying country Sweden · reported origin Unknown

Reported product description
LED light in the shape of feathers. Product sold online. [7]
Reported risk explanation
The plastic material of the cable has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value: 29.8% by weight). This phthalate poses a risk to human health and the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive). [7]
Reported measures, verbatim
Type of economic operator taking notified measure(s): DistributorCategory of measure(s): No answer from the importerDate of entry into force: 29/08/2023 [7]

Read the official alert ↗

Garden light · A12/02182/24

Report published 2024-08-16 · notifying country Sweden · reported origin People's Republic of China

Reported product description
Small garden light. Product sold online. [8]
Reported risk explanation
The plastic material of the cable has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) and short-chain chlorinated paraffins (SCCPs) (measured value up to 2.12%, and 0.28% by weight, respectively). This phthalate may harm the health by causing possible damage to the reproductive system and may harm the health of children, causing possible damage to their reproductive system. SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer. The product does not comply with the Persistent Organic Pollutants (POP) Regulation nor with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive). [8]
Reported measures, verbatim
Type of economic operator taking notified measure(s): ImporterCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 05/08/2023 [8]

Read the official alert ↗

What this acquired cohort contains

26 distinct official alert references, published between 2021-12-17 and 2026-05-01. Counts describe the acquired reports, with no market denominator.

Report yearRecorded alerts
20212
20234
202411
20256
20263

Recorded risk labels within this evidence task

Label combinations are source facts within one comparison; they do not create separate guides with identical preparation tasks.

Source selection, exclusions and calculation method

Filter the acquired, completely parsed English weekly XML releases. Deduplicate official alert references. Group by product category and the complete set of conditional evidence-question topics supported by actual risk text. Risk-label combinations remain recorded cohort facets and do not create buyer intents. Brand, product name, model, origin, notifying country, measurement-only changes and different wording of the same questions do not create intents. Unrecognized mechanisms stay internal for enrichment. Count report years and notifying countries deterministically. Display at most eight newest descriptions with at least 40 characters after whitespace normalization, nonempty reported measures and distinct casefolded descriptions; break date ties by official identifier. All cohort records count even if their description is shorter or not displayed. This is not a representative sample. Counts concern this acquired corpus only.

One acquired version per official public alert reference. Display at most eight newest distinct product descriptions whose normalized whitespace-collapsed text contains at least 40 characters and has nonempty reported measures; ties sort by official identifier. The complete cohort includes shorter descriptions. This is an explicit display selection, not a representative sample.

8 distinct descriptions displayed; 18 cohort records not displayed. Missing fields: {}.

These are selected, dated enforcement observations in the acquired weekly reports, not a random market sample, market-wide failure rate, proof of current product status, or a determination about your product. Notification country is not a complete sales-market or jurisdiction-coverage field. A quoted legal/standard reference is the report’s statement, not independently verified current law or a mandatory test panel.

Calculation safety-gate-evidence-comparison-10; units recorded alerts; no incidence denominator.

Turn the reported failure mechanism into a scoped investigation

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Plasticizer identity, material and use — what evidence do we have?

    Identify the actual plasticizer/substance and polymer/component, with composition and use/exposure facts. Similar abbreviations or a general “phthalates” label do not resolve exact identity or applicable conditions. Keep concentrations and legal scope questions separate.

    Useful evidence: Supplier substance/CAS/EC identities, composition and material records, sampled-component results and exact use/actor context.

    Reported context: [1], [2], [3], [4], [5], [6], [7], [8]

  2. Can we trace the affected component, formula or design revision across our supplied products?

    Compare the reported descriptions with your own identifiers and change records. Treat missing or “Unknown” source fields as unresolved; they do not establish that no action was needed.

    Useful evidence: Product identifiers, revision history, supplier/batch traceability and market/operator records.

  3. Who would own an evidence review and any resulting corrective-action decision?

    Read the reported measures as historical observations. Establish your own operator roles, sector-specific rules, decision owner and communication responsibilities before adopting another case’s response.

    Useful evidence: Supply-chain responsibility map, applicable-law review, investigation scope and documented decision/communication workflow.

Work packages and dependencies

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare Find GPSR Responsible Person (EU/NI) | Compare & Get Quotes