Reported risk evidence comparison

Electrical appliances and equipment: ignition/materials, insulation — reported risk evidence

This comparison covers 2 official alert references, including vacuum wrapping machine, portable gasoline generator, published from 2009-09-11 to 2019-08-02. The recorded risks raise separate evidence questions about ignition/materials, insulation. Compare the product features and dated findings below before scoping an investigation. These historical observations do not determine your product’s compliance or a market failure rate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Dated official observations

Compare the product features and reported failure mechanism

The source wording below describes the reported case at that time. Read each complete report before using it in an investigation.

Vacuum wrapping machine · A12/1164/19

Report published 2019-08-02 · notifying country Hungary · reported origin People's Republic of China

Reported product description
Electric vacuum wrapping machine. The colourful cardboard box packaging contains a package of foil and an instruction manual in English. [1]
Reported risk explanation
The electrical insulation is insufficient. The plastic part holding the heater's current conductor connections is flammable. The user could touch accessible live parts and receive an electric shock.Due to the flammability of conductor connections, there is a risk of fire and burns.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60335. [1]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: DistributorCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 09/04/2019Type of economic operator to whom the measure(s) were ordered: DistributorCategory of measure(s): Recall of the product from end usersDate of entry into force: 09/04/2019 [1]

Read the official alert ↗

Portable gasoline generator · 1229/09

Report published 2009-09-11 · notifying country Germany · reported origin People's Republic of China

Reported product description
Generator Standard Set Q/FMH001-1996Red generator contained in a black carry frame, with three 230 V sockets and one red 400 V socket. [2]
Reported risk explanation
The product poses a risk of :1. electric shock, because:- the live components of the electrical conductors are easily accessible,- the electrical conductors are not sufficiently insulated, - the circuit breaker installed is not suitable for this generator;2. fire, because when the generator is switched off to be refuelled after operation, the exhaust temperature is still higher than 230°C. Given the ignition temperature of petrol (200-300°C), there is a potential danger of ignition and skin burns. The product does not comply with the Machinery Directive (98/37/EC), the Low Voltage Directive (LVD) and the relevant European standards EN 12601 and EN 60204. [2]
Reported measures, verbatim
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban ordered by the authorities.Date of entry into force: Unknown [2]

Read the official alert ↗

What this acquired cohort contains

2 distinct official alert references, published between 2009-09-11 and 2019-08-02. Counts describe the acquired reports, with no market denominator.

Report yearRecorded alerts
20091
20191

Recorded risk labels within this evidence task

Label combinations are source facts within one comparison; they do not create separate guides with identical preparation tasks.

Source selection, exclusions and calculation method

Filter the acquired, completely parsed English weekly XML releases. Deduplicate official alert references. Group by product category and the complete set of conditional evidence-question topics supported by actual risk text. Risk-label combinations remain recorded cohort facets and do not create buyer intents. Brand, product name, model, origin, notifying country, measurement-only changes and different wording of the same questions do not create intents. Unrecognized mechanisms stay internal for enrichment. Count report years and notifying countries deterministically. Display at most eight newest descriptions with at least 40 characters after whitespace normalization, nonempty reported measures and distinct casefolded descriptions; break date ties by official identifier. All cohort records count even if their description is shorter or not displayed. This is not a representative sample. Counts concern this acquired corpus only.

One acquired version per official public alert reference. Display at most eight newest distinct product descriptions whose normalized whitespace-collapsed text contains at least 40 characters and has nonempty reported measures; ties sort by official identifier. The complete cohort includes shorter descriptions. This is an explicit display selection, not a representative sample.

2 distinct descriptions displayed; 0 cohort records not displayed. Missing fields: {}.

These are selected, dated enforcement observations in the acquired weekly reports, not a random market sample, market-wide failure rate, proof of current product status, or a determination about your product. Notification country is not a complete sales-market or jurisdiction-coverage field. A quoted legal/standard reference is the report’s statement, not independently verified current law or a mandatory test panel.

Calculation safety-gate-evidence-comparison-10; units recorded alerts; no incidence denominator.

Turn the reported failure mechanism into a scoped investigation

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Power-supply insulation boundaries — what evidence do we have?

    If your product uses a mains supply or adapter, identify the actual power-supply architecture, insulation boundaries and accessible parts. Ask a qualified specialist which design evidence and investigation would address the reported shock mechanism for this configuration. No medical-device standard or pass/fail limit is selected from this alert.

    Useful evidence: Schematics, adapter/component specifications, ratings, insulation/protection design and configuration-specific existing test evidence.

    Reported context: [1], [2]

  2. Material, ignition and use context — what evidence do we have?

    Identify the relevant material/component and exposure to the reported ignition mechanism. Document product configuration and intended use before agreeing justified methods and criteria. The recorded fire concern does not select a complete mandatory test panel.

    Useful evidence: Material/component specifications, product/use configuration, supplier and existing ignition/thermal evidence.

    Reported context: [1], [2]

  3. Can we trace the affected component, formula or design revision across our supplied products?

    Compare the reported descriptions with your own identifiers and change records. Treat missing or “Unknown” source fields as unresolved; they do not establish that no action was needed.

    Useful evidence: Product identifiers, revision history, supplier/batch traceability and market/operator records.

  4. Who would own an evidence review and any resulting corrective-action decision?

    Read the reported measures as historical observations. Establish your own operator roles, sector-specific rules, decision owner and communication responsibilities before adopting another case’s response.

    Useful evidence: Supply-chain responsibility map, applicable-law review, investigation scope and documented decision/communication workflow.

Work packages and dependencies

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare Find GPSR Responsible Person (EU/NI) | Compare & Get Quotes