FDA record research

Posterior Cervical Screw System (NKG) — FDA decisions, comparisons and evidence

The 2021–2025 analysis contains 33 selected substantially-equivalent FDA decisions under primary product code NKG. Use it to compare documented submissions and evidence with your product. A separate 2026 update contains 4 decisions through 2026-09-27. The latest selected decision across the acquired endpoint is dated 2026-09-17. Neither set establishes a suitable predicate or the route for your device. The complete-year window has 33 decisions; the separate all-observed-date count is 119. These denominators describe different date ranges.

Evidence retrieved 2026-10-06. Source versions and topic-specific limits are listed below.

Recorded scope and its declared regulatory reference

An exact FDA-record regulation_number match to one acquired Title 21 section. Records with the same normalized scope definition, class, regulation and recorded submission/GMP flags are grouped. Sparse definitions and generic exemption boilerplate do not qualify. No text-similarity equivalence or legal applicability is inferred.

What scope does the FDA record describe?

Posterior cervical screw systems are intended for use in fusion procedures of the cervical spine and/or craniocervical junction and/or cervicothoracic junction for: 1) spinal fractures and dislocations; 2) deformities; 3) instabilities; 4) failed previous fusions; 5) tumors; 6) inflammatory disorders; 7) spinal degeneration, 8) facet degeneration with instability; and 9) reconstruction following decompression to treat radiculopathy and/or myelopathy. These systems are also intended to stabilize the spine in the absence of fusion for a limited time period in patients with tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

Compare the proposed indication, user, anatomy, technology and operating principle with this actual scope; record differences and unresolved facts.

Cited source

Which current section does the record cite?

§ 888.3075 Posterior cervical screw system. (a) Identification. Posterior cervical screw systems are comprised of multiple, interconnecting components, made from a variety of materials that allow an implant system to be built from the occiput to the upper thoracic spine to fit the patient's anatomical and physiological requirements, as determined by preoperative cross-sectional imaging. Such a spinal assembly consists of a combination of bone anchors via screws ( i.e., occipital screws, cervical lateral mass screws, cervical pedicle screws, C2 pars screws, C2 translaminar screws, C2 transarticular screws), longitudinal members ( e.g., plates, rods, including dual diameter rods, plate/rod combinations), transverse or cross connectors, interconnection mechanisms ( e.g., rod-to-rod connectors, offset connectors), and closure mechanisms ( e.g., set screws, nuts). Posterior cervical screw systems are rigidly fixed devices that do not contain dynamic features, including but not limited to: non-uniform longitudinal elements or features that allow more motion or flexibility compared to rigid systems. Posterior cervical screw systems are intended to provide immobilization and stabilization of spinal segments in patients as an adjunct to fusion for acute and chronic instabilities of the cervical spine and/or craniocervical junction and/or cervicothoracic junction such as: (1) Traumatic spinal fractures and/or traumatic dislocations; (2) deformities; (3) instabilities; (4) failed previous fusions ( e.g., pseudarthrosis); (5) tumors; (6) inflammatory disorders; (7) spinal degeneration, including neck and/or arm pain of discogenic origin as confirmed by imaging studies (radiographs, CT, MRI); (8) degeneration of the facets with instability; and (9) reconstruction following decompression to treat radiculopathy and/or myelopathy. These systems are also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion. (b) Classification. Class II (special controls). The special controls for posterior cervical screw systems are: (1) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (2) Nonclinical performance testing must demonstrate the mechanical function and durability of the implant. (3) Device components must be demonstrated to be biocompatible. (4) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (5) Labeling must include the following: (i) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (ii) Intended use and indications for use including levels of fixation; (iii) Device specific warnings, precautions, and contraindications that include the following statements: (A) “Precaution: Preoperative planning prior to implantation of posterior cervical screw systems should include review of cross-sectional imaging studies ( e.g., CT and/or MRI) to evaluate the patient's cervical anatomy including the transverse foramen, neurologic structures, and the course of the vertebral arteries. If any findings would compromise the placement of these screws, other surgical methods should be considered. In addition, use of intraoperative imaging should be considered to guide and/or verify device placement, as necessary.” (B) “Precaution: Use of posterior cervical pedicle screw fixation at the C3 through C6 spinal levels requires careful consideration and planning beyond that required for lateral mass screws placed at these spinal levels, given the proximity of the vertebral arteries and neurologic structures in relation to the cervical pedicles at these levels.” (iv) Identification of magnetic resonance (MR) compatibility status; (v) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user, and; (vi) Detailed instructions of each surgical step, including device removal. [84 FR 12092, Apr. 1, 2019]

Read the identification, classification, conditions and referenced limitations in the cited section. A numeric reference match is not a buyer classification or exemption determination.

Cited source

Historical FDA comparison

2021–2025: five complete calendar years

Primary code NKG

All statistics in this section use decisions dated 2021-01-01 to 2025-12-31. The partial 2026 update below is excluded from these distributions.

33Selected decisions in these five years
58.0Median receipt-to-decision calendar days
33Valid date pairs in the distribution

The middle 50% of the 33 valid date pairs spans 55.0–108.0 calendar days. This describes selected recorded submissions, including elapsed time outside active FDA review. It is not an FDA review-time measure or a delivery promise.

20217
20227
202310
20243
20256

Compare like submission types

Recorded typeDecisionsValid date pairsMedian calendar daysMiddle 50%
Special99Withheld: n < 20—
Traditional242486.557.0–126.2

Different submission types and evidence packages are not interchangeable. These selected records do not establish that a particular route is available for your product.

Statistical source: FDA openFDA 510(k) decision dataset. Partition 1 Download the identified records and dates (CSV).

Filters, exclusions and reproducible calculation

Deduplicate by official submission ID across the complete current manifest partitions. Select exact primary product code, K-number format and the stated SE decision codes with valid dates. Recent distributions use the five complete calendar years preceding the latest valid endpoint decision year. Partial-year counts compare equal January-to-cutoff periods. Quartiles use linear interpolation at (n-1)*p and are withheld below 20 valid date pairs. The analysis n describes only its declared complete-year window; selected_se_n separately counts all selected recorded dates through the cutoff.

119 selected records across all observed dates; 0 other/invalid identifier or decision-date records excluded. 0 missing or invalid date pairs in the five-year window.

Date fields: date_received → decision_date. Quantiles: Hyndman–Fan type 7: linear interpolation at (n − 1) × p; displayed to one decimal; n ≥ 20 valid pairs.

Receipt-to-decision calendar elapsed time includes time outside active FDA review; it is not FDA review time, a promised project timeline or an estimate of future clearance. This selected recorded cohort does not include all applications or establish a success probability, predicate suitability, market size, current market availability or legal authorization for another product.

Calculation fda-buyer-research-3 · database cutoff 2026-09-27. CSV rows identify each official K-number, cohort, date pair, exclusion reason and source version.

Separate partial-year update

2026 decisions through 2026-09-27

4 selected decisions from 2026-01-01 to 2026-09-27. The equivalent previous-year period contains 4 decisions through 2025-09-27. These counts describe the records; they are not market growth or submission success rates.

Named records to investigate

Latest decisions across the database

These dated records may come from 2026 or earlier years. They are a separate investigation list, not the five-year statistical cohort. Compare the actual indications and technology before considering a record as a comparator.

Official record / deviceRecorded applicantDecisionRecorded typeCalendar days
K254260 ↗The VEGA Cervical Screw SystemGS Medical Co., Ltd.2026-09-17Traditional262
K253195 ↗TAURUS Posterior Occipital-Cervico-Thoracic Spinal SystemsZheJiang Decans Medical Devices Co., Ltd.2026-06-02Traditional249
K254045 ↗CarboClear® Posterior Cervical Screw System; CarboClear® Hybrid Posterior Cervical Screw SystemCarboFix Orthopedics , Ltd.2026-03-16Traditional89
K254165 ↗Infinity™ OCT SystemMedtronic Sofamor Danek USA, Inc.2026-01-21Special30
K252327 ↗CMORE® CT System; CMORE® CT System Navigated InstrumentsIcotec AG2025-11-12Traditional110
K253129 ↗Infinity™ OCT SystemMedtronic Sofamor Danek USA, Inc.2025-10-24Special29
K251725 ↗ANAX™ OCT Spinal SystemCg Medtech Co., Ltd.2025-06-25Special20
K250866 ↗Sovereign Posterior Cervical SystemMet One Technologies, LLC2025-05-20Traditional57

Supporting documents actually acquired

Go beyond the database row

Read the source context, then compare the evidence with your design. Topic locations below are text matches, including possible limitations or negative statements; they are not a mandatory test list.

The documents are a bounded sample of acquired summaries, not complete evidence coverage of the cohort.

Recorded classification context

Known context: US. Match the intended use and design with the recorded category before treating it as applicable.

Source factRecorded value
FDA product codeNKG [1]
Generic device categoryPosterior Cervical Screw System [1]
Recorded scopePosterior cervical screw systems are intended for use in fusion procedures of the cervical spine and/or craniocervical junction and/or cervicothoracic junction for: 1) spinal fractures and dislocations; 2) deformities; 3) instabilities; 4) failed previous fusions; 5) tumors; 6) inflammatory disorders; 7) spinal degeneration, 8) facet degeneration with instability; and 9) reconstruction following decompression to treat radiculopathy and/or myelopathy. These systems are also intended to stabilize the spine in the absence of fusion for a limited time period in patients with tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion. [1]
Recorded class2 [1]
Regulation888.3075 [1]
Medical specialtyOrthopedic [1]

Build a comparison that explains the differences

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Which specific part of the recorded scope fits or differs?

    Put your proposed label and design beside the quoted definition. Record matching facts, differences and missing facts separately; naming the category alone cannot resolve scope.

    Useful evidence: Proposed indication/design and a definition-to-product comparison with source locators.

  2. Have the cited section and its limitations been reviewed?

    Record the applicable paragraph, conditions and cross-referenced limitations after specialist review. Keep a claimed exemption separate from actual establishment, listing and quality-system responsibilities.

    Useful evidence: Dated classification/route rationale and the current provisions relied on, with unresolved conditions.

  3. Compare your intended use with a named decision

    Choose a named record above. Put your proposed claim beside its actual indications-for-use statement. Record different patients, users, anatomy, settings and output claims; do not treat a shared code as proof of equivalence.

    Useful evidence: Your draft indications for use + the selected official summary and its exact page.

  4. Explain the technology and evidence differences

    For each comparison, record the different materials, hardware, software functions and operating conditions. Link each difference to existing evidence or an unresolved evaluation task.

    Useful evidence: A three-column matrix: comparator fact / your design fact / evidence or unresolved gap.

  5. Make the estimate comparable

    Use the 2021–2025 cohort, and compare the recorded submission type before discussing calendar elapsed time. Separate your own preparation work from the recorded receipt-to-decision period.

    Useful evidence: Chosen K numbers, submission types, dates and your own document/test readiness.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — device classification records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 936de5f5d47b9293b702fc32512a79173969fb788c74a63d9b91abe73f3b86a5

  • [1] device-classification-0001-of-0001.json:results[2996] · record 180e5d5e7c99f1941345f52229219f1dca8edba70eafc10a5f69f92e57075da9

FDA 510(k) summary — K254260 ↗

Fri, 02 Oct 2026 17:00:35 GMT · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot e0da5a971e389ccd63fd31f112d9f5e0c0fd4504bfe98cee03fa61d799fdfc61

  • [2] PDF page 7 · record d31dec1533acdc97d6f0f01fe1bbebed69e7c9f15c7dbd1294d080b9d565d514

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services

Find FDA US Agent Services | Compare & Get Quotes · FDA QMSR Transition & Inspection Readiness (ISO 13485 Alignment)