Posterior Cervical Screw Placement Guide (QSD) — FDA decisions, comparisons and evidence
The 2021–2025 analysis contains 2 selected substantially-equivalent FDA decisions under primary product code QSD. Use it to compare documented submissions and evidence with your product. A separate 2026 update contains 0 decisions through 2026-09-27. The latest selected decision across the acquired endpoint is dated 2023-12-07. Neither set establishes a suitable predicate or the route for your device. The complete-year window has 2 decisions; the separate all-observed-date count is 2. These denominators describe different date ranges.
Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.
Recorded scope and its declared regulatory reference
An exact FDA-record regulation_number match to one acquired Title 21 section. Records with the same normalized scope definition, class, regulation and recorded submission/GMP flags are grouped. Sparse definitions and generic exemption boilerplate do not qualify. No text-similarity equivalence or legal applicability is inferred.
What scope does the FDA record describe?
A posterior cervical screw placement guide is intended to be used as a surgical instrument to assist in the intra-operative placement of posterior cervical screws that are used to anchor posterior cervical screw systems on the posterior elements of the spine. The device utilizes anatomic landmarks that are identifiable on pre-operative imaging scans.
Compare the proposed indication, user, anatomy, technology and operating principle with this actual scope; record differences and unresolved facts.
§ 888.3075 Posterior cervical screw system. (a) Identification. Posterior cervical screw systems are comprised of multiple, interconnecting components, made from a variety of materials that allow an implant system to be built from the occiput to the upper thoracic spine to fit the patient's anatomical and physiological requirements, as determined by preoperative cross-sectional imaging. Such a spinal assembly consists of a combination of bone anchors via screws ( i.e., occipital screws, cervical lateral mass screws, cervical pedicle screws, C2 pars screws, C2 translaminar screws, C2 transarticular screws), longitudinal members ( e.g., plates, rods, including dual diameter rods, plate/rod combinations), transverse or cross connectors, interconnection mechanisms ( e.g., rod-to-rod connectors, offset connectors), and closure mechanisms ( e.g., set screws, nuts). Posterior cervical screw systems are rigidly fixed devices that do not contain dynamic features, including but not limited to: non-uniform longitudinal elements or features that allow more motion or flexibility compared to rigid systems. Posterior cervical screw systems are intended to provide immobilization and stabilization of spinal segments in patients as an adjunct to fusion for acute and chronic instabilities of the cervical spine and/or craniocervical junction and/or cervicothoracic junction such as: (1) Traumatic spinal fractures and/or traumatic dislocations; (2) deformities; (3) instabilities; (4) failed previous fusions ( e.g., pseudarthrosis); (5) tumors; (6) inflammatory disorders; (7) spinal degeneration, including neck and/or arm pain of discogenic origin as confirmed by imaging studies (radiographs, CT, MRI); (8) degeneration of the facets with instability; and (9) reconstruction following decompression to treat radiculopathy and/or myelopathy. These systems are also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion. (b) Classification. Class II (special controls). The special controls for posterior cervical screw systems are: (1) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (2) Nonclinical performance testing must demonstrate the mechanical function and durability of the implant. (3) Device components must be demonstrated to be biocompatible. (4) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (5) Labeling must include the following: (i) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (ii) Intended use and indications for use including levels of fixation; (iii) Device specific warnings, precautions, and contraindications that include the following statements: (A) “Precaution: Preoperative planning prior to implantation of posterior cervical screw systems should include review of cross-sectional imaging studies ( e.g., CT and/or MRI) to evaluate the patient's cervical anatomy including the transverse foramen, neurologic structures, and the course of the vertebral arteries. If any findings would compromise the placement of these screws, other surgical methods should be considered. In addition, use of intraoperative imaging should be considered to guide and/or verify device placement, as necessary.” (B) “Precaution: Use of posterior cervical pedicle screw fixation at the C3 through C6 spinal levels requires careful consideration and planning beyond that required for lateral mass screws placed at these spinal levels, given the proximity of the vertebral arteries and neurologic structures in relation to the cervical pedicles at these levels.” (iv) Identification of magnetic resonance (MR) compatibility status; (v) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user, and; (vi) Detailed instructions of each surgical step, including device removal. [84 FR 12092, Apr. 1, 2019]
Read the identification, classification, conditions and referenced limitations in the cited section. A numeric reference match is not a buyer classification or exemption determination.
Deduplicate by official submission ID across the complete current manifest partitions. Select exact primary product code, K-number format and the stated SE decision codes with valid dates. Recent distributions use the five complete calendar years preceding the latest valid endpoint decision year. Partial-year counts compare equal January-to-cutoff periods. Quartiles use linear interpolation at (n-1)*p and are withheld below 20 valid date pairs. The analysis n describes only its declared complete-year window; selected_se_n separately counts all selected recorded dates through the cutoff.
2 selected records across all observed dates; 0 other/invalid identifier or decision-date records excluded. 0 missing or invalid date pairs in the five-year window.
Date fields: date_received → decision_date. Quantiles: Hyndman–Fan type 7: linear interpolation at (n − 1) × p; displayed to one decimal; n ≥ 20 valid pairs.
Receipt-to-decision calendar elapsed time includes time outside active FDA review; it is not FDA review time, a promised project timeline or an estimate of future clearance. This selected recorded cohort does not include all applications or establish a success probability, predicate suitability, market size, current market availability or legal authorization for another product.
Calculation fda-buyer-research-3 · database cutoff 2026-09-27. CSV rows identify each official K-number, cohort, date pair, exclusion reason and source version.
Separate partial-year update
2026 decisions through 2026-09-27
0 selected decisions from 2026-01-01 to 2026-09-27. The equivalent previous-year period contains 0 decisions through 2025-09-27. These counts describe the records; they are not market growth or submission success rates.
Named records to investigate
Latest decisions across the database
These dated records may come from 2026 or earlier years. They are a separate investigation list, not the five-year statistical cohort. Compare the actual indications and technology before considering a record as a comparator.
Read the source context, then compare the evidence with your design. Topic locations below are text matches, including possible limitations or negative statements; they are not a mandatory test list.
A posterior cervical screw placement guide is intended to be used as a surgical instrument to assist in the intra-operative placement of posterior cervical screws that are used to anchor posterior cervical screw systems on the posterior elements of the spine. The device utilizes anatomic landmarks that are identifiable on pre-operative imaging scans. [1]
Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.
Which specific part of the recorded scope fits or differs?
Put your proposed label and design beside the quoted definition. Record matching facts, differences and missing facts separately; naming the category alone cannot resolve scope.
Useful evidence: Proposed indication/design and a definition-to-product comparison with source locators.
Have the cited section and its limitations been reviewed?
Record the applicable paragraph, conditions and cross-referenced limitations after specialist review. Keep a claimed exemption separate from actual establishment, listing and quality-system responsibilities.
Useful evidence: Dated classification/route rationale and the current provisions relied on, with unresolved conditions.
Compare your intended use with a named decision
Choose a named record above. Put your proposed claim beside its actual indications-for-use statement. Record different patients, users, anatomy, settings and output claims; do not treat a shared code as proof of equivalence.
Useful evidence: Your draft indications for use + the selected official summary and its exact page.
Explain the technology and evidence differences
For each comparison, record the different materials, hardware, software functions and operating conditions. Link each difference to existing evidence or an unresolved evaluation task.
Useful evidence: A three-column matrix: comparator fact / your design fact / evidence or unresolved gap.
Prepare a scope-based schedule without a sparse timing benchmark
This recent cohort has fewer than 20 valid date pairs, so it supplies no median or percentile benchmark. Ask for a schedule based on actual preparation, evidence gaps, interactions and response assumptions; keep any historical decision context separately dated.
Useful evidence: Document/test readiness, unresolved route/evidence tasks and the assumptions behind the specialist’s proposed sequence.
Work packages and dependencies
Conditional: FDA 510(k) Submission Services — Review the supplied facts and evidence gaps before confirming the service scope.
Optional: Find FDA US Agent Services | Compare & Get Quotes — Include only if your product, actor and delivery needs justify this additional scope. Confirm the responsibility and evidence handoff with the coordinating specialist.
Optional: FDA QMSR Transition & Inspection Readiness (ISO 13485 Alignment) — Include only if your product, actor and delivery needs justify this additional scope. Confirm the responsibility and evidence handoff with the coordinating specialist.
What needs to happen first
FDA 510(k) Submission Services → Find FDA US Agent Services | Compare & Get Quotes: Confirm the main product/actor scope and evidence gaps before deciding whether to commission this additional service.
FDA 510(k) Submission Services → FDA QMSR Transition & Inspection Readiness (ISO 13485 Alignment): Confirm the main product/actor scope and evidence gaps before deciding whether to commission this additional service.
Questions for providers
Which of the named QSD decisions are actually comparable to our proposed indications and technology, and which would you exclude?
Which evidence differences prevent us from using the comparison yet, and what deliverable resolves each one?
Does your schedule separate submission preparation, testing, FDA interactions and customer response time? What assumptions change it?
Sources and data dates
Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.