FDA record research

Oximeter, Tissue Saturation, Reprocessed (NMD) — FDA decisions, comparisons and evidence

The acquired FDA endpoint has no selected substantially-equivalent K-number decisions under primary product code NMD during 2021–2025. Its latest selected record across the endpoint is dated 2011-06-08. Use that dated record only as historical context. Check the recorded scope and current route separately; these data do not provide a recent timing benchmark. The complete-year window has 0 decisions; the separate all-observed-date count is 2. These denominators describe different date ranges.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Recorded scope and its declared regulatory reference

An exact FDA-record regulation_number match to one acquired Title 21 section. Records with the same normalized scope definition, class, regulation and recorded submission/GMP flags are grouped. Sparse definitions and generic exemption boilerplate do not qualify. No text-similarity equivalence or legal applicability is inferred.

What scope does the FDA record describe?

Reprocessing validation data for this device type must be included in a 510(k) submission. (70 FR 56911, available at https://www.govinfo.gov/content/pkg/FR-2005-09-29/pdf/05-19510.pdf).

Compare the proposed indication, user, anatomy, technology and operating principle with this actual scope; record differences and unresolved facts.

Cited source

Which current section does the record cite?

§ 870.2700 Oximeter. (a) Identification. An oximeter is a device used to transmit radiation at a known wavelength(s) through blood and to measure the blood oxygen saturation based on the amount of reflected or scattered radiation. It may be used alone or in conjunction with a fiberoptic oximeter catheter. (b) Classification. Class II (performance standards).

Read the identification, classification, conditions and referenced limitations in the cited section. A numeric reference match is not a buyer classification or exemption determination.

Cited source

Historical FDA comparison

2021–2025: five complete calendar years

Primary code NMD

All statistics in this section use decisions dated 2021-01-01 to 2025-12-31. The partial 2026 update below is excluded from these distributions.

0Selected decisions in these five years
WithheldMedian receipt-to-decision calendar days
0Valid date pairs in the distribution

There are 0 valid recent date pairs. Distribution summaries require at least 20; older records are not substituted for a current benchmark.

20210
20220
20230
20240
20250

Statistical source: FDA openFDA 510(k) decision dataset. Partition 1 Download the identified records and dates (CSV).

Filters, exclusions and reproducible calculation

Deduplicate by official submission ID across the complete current manifest partitions. Select exact primary product code, K-number format and the stated SE decision codes with valid dates. Recent distributions use the five complete calendar years preceding the latest valid endpoint decision year. Partial-year counts compare equal January-to-cutoff periods. Quartiles use linear interpolation at (n-1)*p and are withheld below 20 valid date pairs. The analysis n describes only its declared complete-year window; selected_se_n separately counts all selected recorded dates through the cutoff.

2 selected records across all observed dates; 0 other/invalid identifier or decision-date records excluded. 0 missing or invalid date pairs in the five-year window.

Date fields: date_received → decision_date. Quantiles: Hyndman–Fan type 7: linear interpolation at (n − 1) × p; displayed to one decimal; n ≥ 20 valid pairs.

Receipt-to-decision calendar elapsed time includes time outside active FDA review; it is not FDA review time, a promised project timeline or an estimate of future clearance. This selected recorded cohort does not include all applications or establish a success probability, predicate suitability, market size, current market availability or legal authorization for another product.

Calculation fda-buyer-research-3 · database cutoff 2026-09-27. CSV rows identify each official K-number, cohort, date pair, exclusion reason and source version.

Separate partial-year update

2026 decisions through 2026-09-27

0 selected decisions from 2026-01-01 to 2026-09-27. The equivalent previous-year period contains 0 decisions through 2025-09-27. These counts describe the records; they are not market growth or submission success rates.

Named records to investigate

Latest decisions across the database

These dated records may come from 2026 or earlier years. They are a separate investigation list, not the five-year statistical cohort. Compare the actual indications and technology before considering a record as a comparator.

Official record / deviceRecorded applicantDecisionRecorded typeCalendar days
K111007 ↗MIDWEST REPROCESSING CENTER REPROCESSED LNCS SESSORS; MIDWEST REPROCESSING CENTER REPROCESSED OXIMAX SENSORS; MIDWEST REMidwest Reprocessing Center, LLC2011-06-08Traditional58
K100523 ↗ADULT CEREBRAL-SOMATIC OXIMETRY SENSOR, PEDIATRIC CEREBRAL-SOMATIC OXIMETRY SENSOR MODEL HHS-SAFB-SM, HHS-SPFB-USAHygia Health Services, Inc.2010-05-04Traditional69

Supporting documents actually acquired

Go beyond the database row

Read the source context, then compare the evidence with your design. Topic locations below are text matches, including possible limitations or negative statements; they are not a mandatory test list.

The documents are a bounded sample of acquired summaries, not complete evidence coverage of the cohort.

Recorded classification context

Known context: US. Match the intended use and design with the recorded category before treating it as applicable.

Source factRecorded value
FDA product codeNMD [1]
Generic device categoryOximeter, Tissue Saturation, Reprocessed [1]
Recorded scopeReprocessing validation data for this device type must be included in a 510(k) submission. (70 FR 56911, available at https://www.govinfo.gov/content/pkg/FR-2005-09-29/pdf/05-19510.pdf). [1]
Recorded class2 [1]
Regulation870.2700 [1]
Medical specialtyCardiovascular [1]

Build a comparison that explains the differences

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Which specific part of the recorded scope fits or differs?

    Put your proposed label and design beside the quoted definition. Record matching facts, differences and missing facts separately; naming the category alone cannot resolve scope.

    Useful evidence: Proposed indication/design and a definition-to-product comparison with source locators.

  2. Have the cited section and its limitations been reviewed?

    Record the applicable paragraph, conditions and cross-referenced limitations after specialist review. Keep a claimed exemption separate from actual establishment, listing and quality-system responsibilities.

    Useful evidence: Dated classification/route rationale and the current provisions relied on, with unresolved conditions.

  3. Separate historical research from a recent comparator

    No selected decision falls in the complete-year window. Any named records shown are separately dated historical or current-year research. Obtain their actual indications and assess the current route before using a comparator; the absence of a recent record does not establish an exemption or a route.

    Useful evidence: Proposed indication/design, the dated named record if available, and a current route/comparator research rationale.

  4. Explain the technology and evidence differences

    For each comparison, record the different materials, hardware, software functions and operating conditions. Link each difference to existing evidence or an unresolved evaluation task.

    Useful evidence: A three-column matrix: comparator fact / your design fact / evidence or unresolved gap.

  5. Prepare a scope-based schedule without a sparse timing benchmark

    This recent cohort has fewer than 20 valid date pairs, so it supplies no median or percentile benchmark. Ask for a schedule based on actual preparation, evidence gaps, interactions and response assumptions; keep any historical decision context separately dated.

    Useful evidence: Document/test readiness, unresolved route/evidence tasks and the assumptions behind the specialist’s proposed sequence.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — device classification records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 936de5f5d47b9293b702fc32512a79173969fb788c74a63d9b91abe73f3b86a5

  • [1] device-classification-0001-of-0001.json:results[6593] · record a85035bce13d2b62e2118e8d07a72146ca08fc1219495e97dbcd6109749d89d0

FDA 510(k) summary — K111007 ↗

Mon, 25 Jul 2011 04:34:32 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot fa9b15b9f65d3e5e488b746b225795fdf543cfe45d1b21bdb4ce3818425a7fc4

  • [3] PDF page 2 · record f2b8641423a1094b266c78ca45479bcdf160c2e1cb936ef28ee72ede65a94c2a

FDA 510(k) summary — K100523 ↗

Mon, 07 Jun 2010 12:09:32 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 287a77d620e2de1f18b24acbd52c330880485b88dcdea113f7b777b475dab880

  • [4] PDF page 2 · record c46ba3af474f2392322e86fc02d08ccb37a0de8ea03037cb891ac019d4836d07

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services

Find FDA US Agent Services | Compare & Get Quotes · FDA QMSR Transition & Inspection Readiness (ISO 13485 Alignment)