FDA record research

Dental Navigation System (QRY) — FDA decisions, comparisons and evidence

The 2021–2025 analysis contains 4 selected substantially-equivalent FDA decisions under primary product code QRY. Use it to compare documented submissions and evidence with your product. A separate 2026 update contains 1 decisions through 2026-09-27. The latest selected decision across the acquired endpoint is dated 2026-08-28. Neither set establishes a suitable predicate or the route for your device. The complete-year window has 4 decisions; the separate all-observed-date count is 5. These denominators describe different date ranges.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Recorded scope and its declared regulatory reference

An exact FDA-record regulation_number match to one acquired Title 21 section. Records with the same normalized scope definition, class, regulation and recorded submission/GMP flags are grouped. Sparse definitions and generic exemption boilerplate do not qualify. No text-similarity equivalence or legal applicability is inferred.

What scope does the FDA record describe?

Intended to provide real-time guidance on the orientation and location of the dental instrument relative to the patient's anatomy for general dentistry procedures.

Compare the proposed indication, user, anatomy, technology and operating principle with this actual scope; record differences and unresolved facts.

Cited source

Which current section does the record cite?

§ 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use in reconstructive oral surgery to drill or cut into the upper or lower jaw and may be used to prepare bone to insert a wire, pin, or screw. The device includes the manual bone drill and wire driver, powered bone drill, rotary bone cutting handpiece, and AC-powered bone saw. (b) Classification. Class II.

Read the identification, classification, conditions and referenced limitations in the cited section. A numeric reference match is not a buyer classification or exemption determination.

Cited source

Historical FDA comparison

2021–2025: five complete calendar years

Primary code QRY

All statistics in this section use decisions dated 2021-01-01 to 2025-12-31. The partial 2026 update below is excluded from these distributions.

4Selected decisions in these five years
WithheldMedian receipt-to-decision calendar days
4Valid date pairs in the distribution

There are 4 valid recent date pairs. Distribution summaries require at least 20; older records are not substituted for a current benchmark.

20210
20223
20230
20241
20250

Statistical source: FDA openFDA 510(k) decision dataset. Partition 1 Download the identified records and dates (CSV).

Filters, exclusions and reproducible calculation

Deduplicate by official submission ID across the complete current manifest partitions. Select exact primary product code, K-number format and the stated SE decision codes with valid dates. Recent distributions use the five complete calendar years preceding the latest valid endpoint decision year. Partial-year counts compare equal January-to-cutoff periods. Quartiles use linear interpolation at (n-1)*p and are withheld below 20 valid date pairs. The analysis n describes only its declared complete-year window; selected_se_n separately counts all selected recorded dates through the cutoff.

5 selected records across all observed dates; 0 other/invalid identifier or decision-date records excluded. 0 missing or invalid date pairs in the five-year window.

Date fields: date_received → decision_date. Quantiles: Hyndman–Fan type 7: linear interpolation at (n − 1) × p; displayed to one decimal; n ≥ 20 valid pairs.

Receipt-to-decision calendar elapsed time includes time outside active FDA review; it is not FDA review time, a promised project timeline or an estimate of future clearance. This selected recorded cohort does not include all applications or establish a success probability, predicate suitability, market size, current market availability or legal authorization for another product.

Calculation fda-buyer-research-3 · database cutoff 2026-09-27. CSV rows identify each official K-number, cohort, date pair, exclusion reason and source version.

Separate partial-year update

2026 decisions through 2026-09-27

1 selected decisions from 2026-01-01 to 2026-09-27. The equivalent previous-year period contains 0 decisions through 2025-09-27. These counts describe the records; they are not market growth or submission success rates.

Named records to investigate

Latest decisions across the database

These dated records may come from 2026 or earlier years. They are a separate investigation list, not the five-year statistical cohort. Compare the actual indications and technology before considering a record as a comparator.

Official record / deviceRecorded applicantDecisionRecorded typeCalendar days
K253954 ↗X-Guide Surgical Navigation SystemX-Nav Technologies, LLC2026-08-28Traditional261
K232148 ↗X-Guide Surgical Navigation SystemX-Nav Technologies, LLC2024-02-21Traditional217
K222750 ↗Yomi Robotic SystemNeocis, Inc.2022-12-08Traditional87
K222049 ↗Yomi Robotic SystemNeocis, Inc.2022-11-04Traditional115
K211701 ↗X-Guide® Surgical Navigation SystemX-Nav Technologies, LLC2022-02-01Traditional243

Supporting documents actually acquired

Go beyond the database row

Read the source context, then compare the evidence with your design. Topic locations below are text matches, including possible limitations or negative statements; they are not a mandatory test list.

K253954 · official summary PDF ↗

K232148 · official summary PDF ↗

The documents are a bounded sample of acquired summaries, not complete evidence coverage of the cohort.

Recorded classification context

Known context: US. Match the intended use and design with the recorded category before treating it as applicable.

Source factRecorded value
FDA product codeQRY [1]
Generic device categoryDental Navigation System [1]
Recorded scopeIntended to provide real-time guidance on the orientation and location of the dental instrument relative to the patient's anatomy for general dentistry procedures. [1]
Recorded class2 [1]
Regulation872.4120 [1]
Medical specialtyDental [1]

Build a comparison that explains the differences

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Which specific part of the recorded scope fits or differs?

    Put your proposed label and design beside the quoted definition. Record matching facts, differences and missing facts separately; naming the category alone cannot resolve scope.

    Useful evidence: Proposed indication/design and a definition-to-product comparison with source locators.

  2. Have the cited section and its limitations been reviewed?

    Record the applicable paragraph, conditions and cross-referenced limitations after specialist review. Keep a claimed exemption separate from actual establishment, listing and quality-system responsibilities.

    Useful evidence: Dated classification/route rationale and the current provisions relied on, with unresolved conditions.

  3. Compare your intended use with a named decision

    Choose a named record above. Put your proposed claim beside its actual indications-for-use statement. Record different patients, users, anatomy, settings and output claims; do not treat a shared code as proof of equivalence.

    Useful evidence: Your draft indications for use + the selected official summary and its exact page.

  4. Explain the technology and evidence differences

    For each comparison, record the different materials, hardware, software functions and operating conditions. Link each difference to existing evidence or an unresolved evaluation task.

    Useful evidence: A three-column matrix: comparator fact / your design fact / evidence or unresolved gap.

  5. Prepare a scope-based schedule without a sparse timing benchmark

    This recent cohort has fewer than 20 valid date pairs, so it supplies no median or percentile benchmark. Ask for a schedule based on actual preparation, evidence gaps, interactions and response assumptions; keep any historical decision context separately dated.

    Useful evidence: Document/test readiness, unresolved route/evidence tasks and the assumptions behind the specialist’s proposed sequence.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — device classification records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 936de5f5d47b9293b702fc32512a79173969fb788c74a63d9b91abe73f3b86a5

  • [1] device-classification-0001-of-0001.json:results[5106] · record 3cd23893a0bc8fc17eeec284dda80dc6dc1fd657bde5b7d0629a3bae16e23cc3

FDA 510(k) summary — K253954 ↗

Fri, 04 Sep 2026 11:21:58 GMT · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 9d4dc81c890b53a0f85d9a4102d821354f37836e747289a9924dfa8287769a75

  • [2] PDF page 16 · record 5371c4b30ea4423361fa5625bb45d9a8b562049fd513582b53ee8323f7d47bb1
  • [3] PDF page 18 · record 70a3f331d05a397cd362b2ef7d42634f22dc8c2568519dd885bb7f650f78cfb3

FDA 510(k) summary — K232148 ↗

Thu, 22 Feb 2024 17:57:04 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot abb1741c7906058726840fbf721fa425d66418370f48f6701cacfec25afe5a8c

  • [5] PDF page 16 · record edf757011fdf9941116710935c0628ca40a34b628addcd758cab18d3585b78a3
  • [6] PDF page 20 · record 389e7b81802f9b4eba37c28d359dafc98d93bb91c03016844b8a63e53f017e71

FDA 510(k) summary — K222750 ↗

Fri, 09 Dec 2022 13:27:32 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 0ab49c59e5f855bf1674e78c57182c57eb2305c2bbdc17b580a02c2abc4e00ff

  • [7] PDF page 7 · record 73ac741c5059d22cf103d25ef57a8a6965e821be9833900449164a96e9154d39
  • [8] PDF page 8 · record 5d77a5a41a7754c9654b863bccf8eef7245e3450fa5943872f4bdf8fd73ef0ea

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services

Find FDA US Agent Services | Compare & Get Quotes · FDA QMSR Transition & Inspection Readiness (ISO 13485 Alignment)