FDA record research

Barrier, Animal Source, Intraoral (NPL) — FDA decisions, comparisons and evidence

The 2021–2025 analysis contains 15 selected substantially-equivalent FDA decisions under primary product code NPL. Use it to compare documented submissions and evidence with your product. A separate 2026 update contains 0 decisions through 2026-09-27. The latest selected decision across the acquired endpoint is dated 2025-12-12. Neither set establishes a suitable predicate or the route for your device. The complete-year window has 15 decisions; the separate all-observed-date count is 57. These denominators describe different date ranges.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Recorded scope and its declared regulatory reference

An exact FDA-record regulation_number match to one acquired Title 21 section. Records with the same normalized scope definition, class, regulation and recorded submission/GMP flags are grouped. Sparse definitions and generic exemption boilerplate do not qualify. No text-similarity equivalence or legal applicability is inferred.

What scope does the FDA record describe?

An animal source dental barrier is an animal-derived material device, such as collagen, intended to aid in guided tissue/bone regeneration procedures and to act as a stable barrier for the containment of bone graft materials when placed around implants.

Compare the proposed indication, user, anatomy, technology and operating principle with this actual scope; record differences and unresolved facts.

Cited source

Which current section does the record cite?

§ 872.3930 Bone grafting material. (a) Identification. Bone grafting material is a material such as hydroxyapatite, tricalcium phosphate, polylactic and polyglycolic acids, or collagen, that is intended to fill, augment, or reconstruct periodontal or bony defects of the oral and maxillofacial region. (b) Classification. (1) Class II (special controls) for bone grafting materials that do not contain a drug that is a therapeutic biologic. The special control is FDA's “Class II Special Controls Guidance Document: Dental Bone Grafting Material Devices.” (See § 872.1(e) for the availability of this guidance document.) (2) Class III (premarket approval) for bone grafting materials that contain a drug that is a therapeutic biologic. Bone grafting materials that contain a drug that is a therapeutic biologic, such as biological response modifiers, require premarket approval. (c) Date premarket approval application (PMA) or notice of product development protocol (PDP) is required. Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution. [70 FR 21949, Apr. 28, 2005]

Read the identification, classification, conditions and referenced limitations in the cited section. A numeric reference match is not a buyer classification or exemption determination.

Cited source

Historical FDA comparison

2021–2025: five complete calendar years

Primary code NPL

All statistics in this section use decisions dated 2021-01-01 to 2025-12-31. The partial 2026 update below is excluded from these distributions.

15Selected decisions in these five years
WithheldMedian receipt-to-decision calendar days
15Valid date pairs in the distribution

There are 15 valid recent date pairs. Distribution summaries require at least 20; older records are not substituted for a current benchmark.

20212
20223
20232
20243
20255

Compare like submission types

Recorded typeDecisionsValid date pairsMedian calendar daysMiddle 50%
Special22Withheld: n < 20—
Traditional1313Withheld: n < 20—

Different submission types and evidence packages are not interchangeable. These selected records do not establish that a particular route is available for your product.

Statistical source: FDA openFDA 510(k) decision dataset. Partition 1 Download the identified records and dates (CSV).

Filters, exclusions and reproducible calculation

Deduplicate by official submission ID across the complete current manifest partitions. Select exact primary product code, K-number format and the stated SE decision codes with valid dates. Recent distributions use the five complete calendar years preceding the latest valid endpoint decision year. Partial-year counts compare equal January-to-cutoff periods. Quartiles use linear interpolation at (n-1)*p and are withheld below 20 valid date pairs. The analysis n describes only its declared complete-year window; selected_se_n separately counts all selected recorded dates through the cutoff.

57 selected records across all observed dates; 0 other/invalid identifier or decision-date records excluded. 0 missing or invalid date pairs in the five-year window.

Date fields: date_received → decision_date. Quantiles: Hyndman–Fan type 7: linear interpolation at (n − 1) × p; displayed to one decimal; n ≥ 20 valid pairs.

Receipt-to-decision calendar elapsed time includes time outside active FDA review; it is not FDA review time, a promised project timeline or an estimate of future clearance. This selected recorded cohort does not include all applications or establish a success probability, predicate suitability, market size, current market availability or legal authorization for another product.

Calculation fda-buyer-research-3 · database cutoff 2026-09-27. CSV rows identify each official K-number, cohort, date pair, exclusion reason and source version.

Separate partial-year update

2026 decisions through 2026-09-27

0 selected decisions from 2026-01-01 to 2026-09-27. The equivalent previous-year period contains 2 decisions through 2025-09-27. These counts describe the records; they are not market growth or submission success rates.

Named records to investigate

Latest decisions across the database

These dated records may come from 2026 or earlier years. They are a separate investigation list, not the five-year statistical cohort. Compare the actual indications and technology before considering a record as a comparator.

Official record / deviceRecorded applicantDecisionRecorded typeCalendar days
K242817 ↗Jason membraneBotiss Biomaterials GmbH2025-12-12Traditional450
K250512 ↗Augmented Gingival MatrixNeo Modulus (Suzhou) Medical Sci-Tech Co., Ltd.2025-12-05Traditional287
K252253 ↗Geistlich Mucograft® /Geistlich Mucograft® Seal; Geistlich Fibro-Gide®Geistlich Pharma AG2025-11-25Traditional127
K251062 ↗Geistlich Bio-Gide; Geistlich Bio-Gide® Shape; Geistlich Bio-Gide® Compressed; Geistlich Bio-Gide® Forte; Geistlich Bio-Gide® Perio; Geistlich Combi-Kit Collagen®; Geistlich Perio-System Combi PackGeistlich Pharma AG2025-08-14Traditional132
K250833 ↗SwissMembrane X; SwissMembrane X SocketGeistlich Pharma AG2025-04-15Special27
K233203 ↗Soft Tissue Augmentation Resorbable MatrixCollagen Matrix, Inc.2024-05-01Traditional216
K231513 ↗Oral MatrixBeijing Biosis Healing Biolog Ical Technology Co., Ltd.2024-02-16Traditional267
K231305 ↗Endoform Dental MembraneAroa Biosurgery , Ltd.2024-01-23Traditional263

Supporting documents actually acquired

Go beyond the database row

Read the source context, then compare the evidence with your design. Topic locations below are text matches, including possible limitations or negative statements; they are not a mandatory test list.

K242817 · official summary PDF ↗

K250512 · official summary PDF ↗

K252253 · official summary PDF ↗

The documents are a bounded sample of acquired summaries, not complete evidence coverage of the cohort.

Recorded classification context

Known context: US. Match the intended use and design with the recorded category before treating it as applicable.

Source factRecorded value
FDA product codeNPL [1]
Generic device categoryBarrier, Animal Source, Intraoral [1]
Recorded scopeAn animal source dental barrier is an animal-derived material device, such as collagen, intended to aid in guided tissue/bone regeneration procedures and to act as a stable barrier for the containment of bone graft materials when placed around implants. [1]
Recorded class2 [1]
Regulation872.3930 [1]
Medical specialtyDental [1]

Build a comparison that explains the differences

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Which specific part of the recorded scope fits or differs?

    Put your proposed label and design beside the quoted definition. Record matching facts, differences and missing facts separately; naming the category alone cannot resolve scope.

    Useful evidence: Proposed indication/design and a definition-to-product comparison with source locators.

  2. Have the cited section and its limitations been reviewed?

    Record the applicable paragraph, conditions and cross-referenced limitations after specialist review. Keep a claimed exemption separate from actual establishment, listing and quality-system responsibilities.

    Useful evidence: Dated classification/route rationale and the current provisions relied on, with unresolved conditions.

  3. Compare your intended use with a named decision

    Choose a named record above. Put your proposed claim beside its actual indications-for-use statement. Record different patients, users, anatomy, settings and output claims; do not treat a shared code as proof of equivalence.

    Useful evidence: Your draft indications for use + the selected official summary and its exact page.

  4. Explain the technology and evidence differences

    For each comparison, record the different materials, hardware, software functions and operating conditions. Link each difference to existing evidence or an unresolved evaluation task.

    Useful evidence: A three-column matrix: comparator fact / your design fact / evidence or unresolved gap.

  5. Prepare a scope-based schedule without a sparse timing benchmark

    This recent cohort has fewer than 20 valid date pairs, so it supplies no median or percentile benchmark. Ask for a schedule based on actual preparation, evidence gaps, interactions and response assumptions; keep any historical decision context separately dated.

    Useful evidence: Document/test readiness, unresolved route/evidence tasks and the assumptions behind the specialist’s proposed sequence.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — device classification records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 936de5f5d47b9293b702fc32512a79173969fb788c74a63d9b91abe73f3b86a5

  • [1] device-classification-0001-of-0001.json:results[1066] · record 24e09c8de4f27e5f0b36013e13541867a47ff3b1370cfaf1155db1fa70864554

FDA 510(k) summary — K242817 ↗

Thu, 08 Jan 2026 13:14:56 GMT · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot a1a76920966f53c36662dd9ad749373b4a481e65d4031e576c657bdf41eac247

  • [2] PDF page 8 · record 279ac2b0ddeac75086691d7110638ea655423501f41116154f991e0196402e7f

FDA 510(k) summary — K250512 ↗

Thu, 08 Jan 2026 13:17:05 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot a671096176218deefe468c2c1a913e01fa6ed59a4fd9de893dffed4356610c13

  • [4] PDF page 7 · record 70180431235b8e286b1803468e9c067051c666bcad330388f3d250d4604cc95c
  • [5] PDF page 10 · record 9b13d24ac07b18d16791990484130784817edb93d976ad5f556f45602bf1d664

FDA 510(k) summary — K252253 ↗

Fri, 05 Dec 2025 21:00:03 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 42ea173f607252fa7486f1cced62274e66166af89d3947fc100eeea4e6bb12f8

  • [6] PDF page 6 · record 9511923abfbd686d99e09d82e81320f24cd5571cf85818c0a1a2c885dcbbf54d
  • [7] PDF page 7 · record 5d8ac8d90a0f15aa92cbabf95ddfd421829fee9e555ba26742f5d9b1b19d7ab0
  • [8] PDF page 10 · record fe67a9920d08eb628185716441cb1aac6a91c8587a545dc6b64c92075aaa9bfd