Recorded device evidence

ThermAffyx(TM) Patient Safety System (K260278): indications, design and recorded evidence

The acquired K260278 file contains product-specific indications and users, design and operating principle, non-clinical evidence actually described sections. Compare these dated manufacturer statements with your own indication and design before commissioning evidence work. They describe this submission; they do not prescribe your testing, validate performance independently or establish a suitable predicate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Computed exact-code research

This decision beside its recorded product-code cohort

The 2021–2025 complete-year cohort contains 15 selected decisions under primary code DWJ. 15 have valid reported receipt/decision pairs; 0 pairs are missing or invalid.

No quartiles are displayed: this complete-year cohort has fewer than 20 valid pairs.

The table shows the named decision and up to four latest exact-code research records through 2026-09-27. It can include partial-year records outside the complete-year cohort. The quartiles above use the full stated cohort, not this displayed selection.

Research recordRecorded deviceReceipt → decisionCalendar elapsed daysRecorded submission type
K260278 ↗ · this pageThermAffyx(TM) Patient Safety System2026-01-29 → 2026-07-08160Traditional
K262089 ↗Disposable Warming Blanket2026-06-22 → 2026-08-2160Traditional
K261437 ↗Mistral-Air® Warming System2026-04-30 → 2026-08-0799Special
K260903 ↗Hot Pink Pad Warming System2026-03-18 → 2026-04-1629Traditional
K252861 ↗Warming System2025-09-09 → 2026-04-07210Traditional

Use this comparison: select a record to investigate, read its actual indications and design, and document differences. A shared code or elapsed period cannot establish its relevance to your device.

Calendar elapsed days are not active FDA review time, a promised schedule or a success probability. The selection includes only the stated recorded decisions, not all applications. Latest records can postdate the named historical decision and are contextual research, not its predicates. Shared codes, summaries and observed records do not prove equivalence, current market availability, buyer applicability or predicate suitability.

Calculation, selection and source versions

Reuse the complete-endpoint exact-primary-code, documented SE-decision cohort and its stated cutoff/window. Retain its type-7 quartiles only when at least 20 valid date pairs are present. Independently subtract the named official record’s receipt date from its decision date; missing or negative pairs remain unknown. Show up to four latest exact-code research records, excluding the named ID. Parent analysis hash, source snapshots and calculation versions are retained.

Calculation: fda-named-decision-cohort-context-1; cutoff 2026-09-27; 0 parent records excluded; units record counts; calendar elapsed days.

Source snapshots: 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002.

Read beyond the decision row

Recorded evidence and differences to investigate

The summary is manufacturer-submitted context hosted by FDA. Negative/no-study statements are preserved. Evidence themes are not binding legal requirements.

Short opening excerpts identify the source sections. Read the linked original for the full study context, negative statements, tables and limitations. Public quotations are limited to 120 words per acquired summary; the internal evidence packet retains exact section ranges for review.

Indications and users

K260278 · PDF page 6 ↗ Source 2

Read this statement in the original PDF; no complete statement fits the short excerpt.

Compare with your product: Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

Design and operating principle

K260278 · PDF page 6 ↗ Source 2

Stihler Electronics GmbH is developing a Patient Warming System and single use disposable pad that can be used
underneath patients during procedures where preventing hypothermia and providing patient securement are needed.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

Non-clinical evidence actually described

K260278 · PDF page 20 ↗ Source 3

Read this statement in the original PDF; no complete statement fits the short excerpt.

Compare with your product: Treat these as documented evidence themes in this case, including any limitations or negative statements. Ask which protocols, design inputs and acceptance rationale would be justified for your product; these excerpts are not a mandatory test panel.

Extraction selection and limits

Select observed whole-line section headings or explicit colon-delimited inline labels on readable PDF pages, including the explicitly documented heading-spacing variants in this parser version. Preserve the original heading, character ranges and layout; do not repair excerpt text. Exclude letter boilerplate and uncertain pages. Stop at observed table headings; do not infer table columns or scalar results from layout text. Multi-column or suspicious split-numeric excerpts are excluded until reviewed alternate extraction is available. Original layout records remain retained; any alternate text has its own extractor-version locator and requires original-page review. For each dimension, prefer usable versioned alternate text where available, selecting its longest usable excerpt; otherwise select the longest usable original-layout excerpt. Ties preserve source order. Bounded to 64 PDF pages and 3,500 characters per section. This is a selection, not a complete dossier analysis.

Excluded extraction items: {}.

Historical references beside dated FDA recognition metadata

Read each mention in the linked original summary, including statements that testing was not performed. Recognition metadata does not determine your testing needs, chosen edition or transition eligibility.

Reference in this historical summaryDesignation in the acquired FDA exportRecognition / entry dateRecorded transition-expiration dateSources
IEC 60601-2-35
o Bench Testing
IEC 60601-2-35 Edition 2.1 2023-12 CONSOLIDATED VERSION
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets pads and mattresses and intended for heating in medical use
6-512 · Complete
05/26/2025
Not recorded in this export rowSummary [3] · Metadata [4]
Read scope and recognition limits ↗
IEC 60601-2-35
o Bench Testing
IEC 60601-2-35 Edition 2.0 2020-09
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets pads and mattresses and intended for heating in medical use
6-483 · Complete
12/19/2022
07/02/2028Summary [3] · Metadata [5]
Read scope and recognition limits ↗
IEC 60601-1
o Bench Testing
IEC 60601-1 Edition 3.2 2020-08 CONSOLIDATED VERSION
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance - Note: This standard is recognized with relevant US national differences applied see references #1 and #2 in the Relevant FDA Guidance and/or Supportive Publication section below.
19-49 · Complete
04/03/2023
Not recorded in this export rowSummary [3] · Metadata [6]
Read scope and recognition limits ↗
IEC 60601-1-8
o Bench Testing
IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION
Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements tests and guidance for alarm systems in medical electrical equipment and medical electrical systems
5-131 · Complete
12/21/2020
Not recorded in this export rowSummary [3] · Metadata [7]
Read scope and recognition limits ↗
IEC 60601-1-8
o Bench Testing
ANSI AAMI IEC 60601-1-8:2006 and A1:2012 [Including AMD 2:2021]
Medical Electrical Equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements tests and guidance for alarm systems in medical electrical equipment and medical electrical systems [Including Amendment 2 (2021)]
5-131 · Complete
12/21/2020
Not recorded in this export rowSummary [3] · Metadata [8]
Read scope and recognition limits ↗
IEC 60601-1-2
o Bench Testing
IEC 60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
19-36 · Partial
12/21/2020
Not recorded in this export rowSummary [3] · Metadata [9]
Read scope and recognition limits ↗
IEC 60601-1-2
o Bench Testing
ANSI AAMI IEC 60601-1-2:2014 [Including AMD 1:2021]
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests [Including Amendment 1 (2021)]
19-36 · Partial
12/21/2020
Not recorded in this export rowSummary [3] · Metadata [10]
Read scope and recognition limits ↗
IEC 60601-1-6
o Bench Testing
IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
5-132 · Complete
12/21/2020
Not recorded in this export rowSummary [3] · Metadata [11]
Read scope and recognition limits ↗

Prepare for your provider: the proposed protocol/report edition, its justification for your device and the complete current FDA recognition sheet. In particular, inspect exclusions for partial recognition. An edition difference does not automatically make the historical evidence unusable.

Identifier-matching method and selection limits

Match explicit ISO/IEC identifiers in selected preserved summary excerpts to the acquired, count-reconciled FDA metadata export. Preserve the historical edition mention, current snapshot designations, entry dates, recognition extent and any recorded transition-expiration date as separate facts. No title-similarity, edition-equivalence, test-mandate or transition-eligibility inference. At most twenty matched occurrences and thirty metadata rows per reference; wide matches are held for separate review.

5 of 5 matched reference occurrences shown.

Known facts and deciding inputs

Known context: US. Confirm the organisation’s role, relevant activities and markets against the cited criteria.

Source factRecorded valueWhat to check
510(k) identifierK260278 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Generic device categoryThermAffyx(TM) Patient Safety System [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded applicantStihler Electronic GmbH [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
FDA product codeDWJ [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Decision date2026-07-08 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded decision codeSESE [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Submission typeTraditional [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Receipt date2026-01-29 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.

Prepare a differences and evidence worksheet

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Indications and users — what differs in our product?

    Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

    Useful evidence: Our proposed indication, user/population and use environment beside this exact recorded indication.

  2. Design and operating principle — what differs in our product?

    Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

    Useful evidence: Design description, materials/components, accessory list and a differences matrix.

  3. Non-clinical evidence actually described — what differs in our product?

    Treat these as documented evidence themes in this case, including any limitations or negative statements. Ask which protocols, design inputs and acceptance rationale would be justified for your product; these excerpts are not a mandatory test panel.

    Useful evidence: Existing protocols/results and design-specific evidence gaps, with standard editions and scope reviewed separately.

  4. Which edition and recognition limits would our provider rely on?

    Compare each historical reference below with the dated FDA metadata. Ask the specialist to justify the applicable scope and selected edition, read the complete supplementary sheet for partial-recognition exclusions, and investigate any recorded transition conditions. A difference in editions does not automatically make the earlier study unusable.

    Useful evidence: Proposed protocol/report edition, dated FDA recognition sheet with scope/exclusions, and a documented edition/transition rationale for the actual device.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — 510(k) decision records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002

  • [1] device-510k-0001-of-0001.json:results[128896] · record 93e68ace38a269f65f7b21c51ef55a4a801e3e92826f23ebbdc4d036463dc284
  • [12] Complete results array / fda-decision-context:K260278 · record whole dataset partition

FDA 510(k) summary — K260278 ↗

Fri, 07 Aug 2026 21:35:09 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot b35e020b706f0433fc1bc9f6de956674aeb466a8cacd3425303904f6291a46de

  • [2] PDF page 6 · record 999c7b3fcd66e83eb0a19135469a50f53bd1d7315cd997014a1c02b96d7f6c68
  • [3] PDF page 20 · record c353066a015f660e1d016a562117800d2f7b38490a257268b05a2960012e2588

FDA — recognition metadata exported through the official search form ↗

Version not stated by the source · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 94ccf56dc846c7f6d78d6ad77dc6e87d1803ac3612af01d6894949e34c4a78d8

  • [4] CSV row 224 · record 47075d5a616ed96d45c62103fbe7badc5815864f5263b6b8eb40cbc31dbac4cf
  • [5] CSV row 606 · record 61053b6c877b1a6a65babe8cbc2a04142e272e78d0b15862f9211367a22e33c1
  • [6] CSV row 578 · record a8ca2ae93456e86990f02a41106f678908bb91d9543453fd2875c48c4cd817d0
  • [7] CSV row 872 · record 90b98409fabb3d43ffca2cc527b1e74939d5b71c95262a1dc1f31d13f76b984e
  • [8] CSV row 873 · record 20e4883c12033b717c25b939a3ed12352c419d783c0eea9bb6c430e2b0f660dc
  • [9] CSV row 876 · record a8f2c7aa5fa6c6ffe1d66d56377f30d7cbd9cdbc2078a3d67e8fdff024e2f0ca
  • [10] CSV row 877 · record 44ad0bacea9459dd513264be920199f91b017f973622203ca12b585f5bc35330
  • [11] CSV row 874 · record 71f87aec0fa1647a7281fcc86caf662d09b288c45d723e06b84f016bf65f4154

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services

Biocompatibility Testing (ISO 10993 Program) · Electrical Safety + EMC Testing (IEC 60601) · Usability / Human Factors Testing