Recorded device evidence

PanopticAI Vital Signs (K240890): indications, design and recorded evidence

The acquired K240890 file contains product-specific indications and users, recorded comparison and differences, performance evidence actually described, clinical evidence or its stated absence sections. Compare these dated manufacturer statements with your own indication and design before commissioning evidence work. They describe this submission; they do not prescribe your testing, validate performance independently or establish a suitable predicate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Computed exact-code research

This decision beside its recorded product-code cohort

The 2021–2025 complete-year cohort contains 8 selected decisions under primary code QME. 8 have valid reported receipt/decision pairs; 0 pairs are missing or invalid.

No quartiles are displayed: this complete-year cohort has fewer than 20 valid pairs.

The table shows the named decision and up to four latest exact-code research records through 2026-09-27. It can include partial-year records outside the complete-year cohort. The quartiles above use the full stated cohort, not this displayed selection.

Research recordRecorded deviceReceipt → decisionCalendar elapsed daysRecorded submission type
K240890 ↗ · this pagePanopticAI Vital Signs2024-04-01 → 2024-12-23266Traditional
K254169 ↗SmartSpectra Vital Signs Monitor 1.02025-12-23 → 2026-06-18177Traditional
K253650 ↗Anura Mobile Core SDK (M1)2025-11-20 → 2026-06-11203Traditional
K260066 ↗PanopticAI Vital Signs (1.6.1-22)2026-01-09 → 2026-05-21132Traditional
K251200 ↗Vital Signs2025-04-18 → 2026-02-02290Traditional

Use this comparison: select a record to investigate, read its actual indications and design, and document differences. A shared code or elapsed period cannot establish its relevance to your device.

Calendar elapsed days are not active FDA review time, a promised schedule or a success probability. The selection includes only the stated recorded decisions, not all applications. Latest records can postdate the named historical decision and are contextual research, not its predicates. Shared codes, summaries and observed records do not prove equivalence, current market availability, buyer applicability or predicate suitability.

Calculation, selection and source versions

Reuse the complete-endpoint exact-primary-code, documented SE-decision cohort and its stated cutoff/window. Retain its type-7 quartiles only when at least 20 valid date pairs are present. Independently subtract the named official record’s receipt date from its decision date; missing or negative pairs remain unknown. Show up to four latest exact-code research records, excluding the named ID. Parent analysis hash, source snapshots and calculation versions are retained.

Calculation: fda-named-decision-cohort-context-1; cutoff 2026-09-27; 1 parent records excluded; units record counts; calendar elapsed days.

Source snapshots: 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002.

Read beyond the decision row

Recorded evidence and differences to investigate

The summary is manufacturer-submitted context hosted by FDA. Negative/no-study statements are preserved. Evidence themes are not binding legal requirements.

Short opening excerpts identify the source sections. Read the linked original for the full study context, negative statements, tables and limitations. Public quotations are limited to 120 words per acquired summary; the internal evidence packet retains exact section ranges for review.

Indications and users

K240890 · PDF page 7 ↗ Source 2

The PanopticAI Vital Signs device is intended for non-invasive spot measurement of pulse rate
       when the subject is still.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

Recorded comparison and differences

K240890 · PDF page 10 ↗ Source 3

The subject device has similar intended use, design, and performance when compared to the
       predicate device. The basic technological and operating principles are the same for both devices.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: The summary’s comparison is a manufacturer statement about that submission. Investigate the actual design differences and cited records before considering any comparator or predicate.

Performance evidence actually described

K240890 · PDF page 11 ↗ Source 4

10.4.1.   Glasses
          A bench test was       undertaken      to verify the accuracy of the PanopticAI Vital Signs app with
          subjects wearing glasses versus those without.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

Clinical evidence or its stated absence

K240890 · PDF page 12 ↗ Source 5

This clinical study aimed to assess the agreement between Vital Sign App and the standard
      pulse rate measurement by a clinician by using Bland-Altman and regression analysis.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Preserve whether the summary describes clinical evidence or says none was performed. This recorded case does not determine whether your product needs clinical evidence.

Extraction selection and limits

Select observed whole-line section headings or explicit colon-delimited inline labels on readable PDF pages, including the explicitly documented heading-spacing variants in this parser version. Preserve the original heading, character ranges and layout; do not repair excerpt text. Exclude letter boilerplate and uncertain pages. Stop at observed table headings; do not infer table columns or scalar results from layout text. Multi-column or suspicious split-numeric excerpts are excluded until reviewed alternate extraction is available. Original layout records remain retained; any alternate text has its own extractor-version locator and requires original-page review. For each dimension, prefer usable versioned alternate text where available, selecting its longest usable excerpt; otherwise select the longest usable original-layout excerpt. Ties preserve source order. Bounded to 64 PDF pages and 3,500 characters per section. This is a selection, not a complete dossier analysis.

Excluded extraction items: {'uncertain_pdf_page': 1}.

Known facts and deciding inputs

Known context: US. Confirm the organisation’s role, relevant activities and markets against the cited criteria.

Source factRecorded valueWhat to check
510(k) identifierK240890 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Generic device categoryPanopticAI Vital Signs [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded applicantPanopticAI technologies Limited [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
FDA product codeQME [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Decision date2024-12-23 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded decision codeSESE [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Submission typeTraditional [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Receipt date2024-04-01 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.

Prepare a differences and evidence worksheet

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Indications and users — what differs in our product?

    Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

    Useful evidence: Our proposed indication, user/population and use environment beside this exact recorded indication.

  2. Recorded comparison and differences — what differs in our product?

    The summary’s comparison is a manufacturer statement about that submission. Investigate the actual design differences and cited records before considering any comparator or predicate.

    Useful evidence: Feature-by-feature differences and the underlying cited documents; no automated predicate selection.

  3. Performance evidence actually described — what differs in our product?

    The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

    Useful evidence: The cited narrative and full tables, underlying protocols/results and a reviewed comparison with the proposed product.

  4. Clinical evidence or its stated absence — what differs in our product?

    Preserve whether the summary describes clinical evidence or says none was performed. This recorded case does not determine whether your product needs clinical evidence.

    Useful evidence: Your proposed claims and supporting evidence, plus a reviewed rationale for clinical-evidence needs.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — 510(k) decision records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002

  • [1] device-510k-0001-of-0001.json:results[6727] · record 142ec96114fdc9fe140a8ca8ba1a4a58e9716294546007b7c4d3832a88f7b74c
  • [6] Complete results array / fda-decision-context:K240890 · record whole dataset partition

FDA 510(k) summary — K240890 ↗

Tue, 24 Dec 2024 20:14:32 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 48dc887bf70edd1775ffe3817e70f61a22592a88964466deb4fe2db975fcd115

  • [2] PDF page 7 · record 504a385a763d57864e6ca5ed338f4c0c0e9eb1e287288fdabaa7dfd890e0ddde
  • [3] PDF page 10 · record 4b9200c0b38e1a6bc2fddf567b19ae5f6bdfff72df940540f208e404fa241043
  • [4] PDF page 11 · record fbdf8e9aa0b680484811328e9b007b3d49f4c1ff7df87bc4b998b64c808c8829
  • [5] PDF page 12 · record ba8c90f112102c97bd6bc1ad41c94b5d1658a31798420abf6daad38bbfe3ba67

Prepare an editable project brief