Reprocessed ViewFlex Xtra ICE Catheter (K182238): indications, design and recorded evidence

The acquired K182238 file contains product-specific indications and users, design and operating principle, recorded comparison and differences, performance evidence actually described sections. Compare these dated manufacturer statements with your own indication and design before commissioning evidence work. They describe this submission; they do not prescribe your testing, validate performance independently or establish a suitable predicate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Computed exact-code research

This decision beside its recorded product-code cohort

The 2021–2025 complete-year cohort contains 14 selected decisions under primary code OWQ. 14 have valid reported receipt/decision pairs; 0 pairs are missing or invalid.

No quartiles are displayed: this complete-year cohort has fewer than 20 valid pairs.

The table shows the named decision and up to four latest exact-code research records through 2026-09-27. It can include partial-year records outside the complete-year cohort. The quartiles above use the full stated cohort, not this displayed selection.

Research recordRecorded deviceReceipt → decisionCalendar elapsed daysRecorded submission type
K182238 ↗ · this pageReprocessed ViewFlex Xtra ICE Catheter2018-08-20 → 2019-05-08261Traditional
K254149 ↗Reprocessed AcuNav CRYSTAL™ Ultrasound Catheter 9F x 90 CM, For Use on Siemens System (R11510825); Reprocessed AcuNav CRYSTAL™ Ultrasound Catheter 9F x 90 CM, For Use on GE System (R11657484); Reprocessed SOUNDSTAR CRYSTAL™ Ultrasound Catheter 9F x 90 CM, For Use on Siemens System (R11510826); Reprocessed SOUNDSTAR CRYSTAL™ Ultrasound Catheter 9F x 90 CM, For Use on GE System (R11657485)2025-12-22 → 2026-06-29189Traditional
K250545 ↗Medline ReNewal Reprocessed Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter (8F, 8FG, 10F, 10FG)2025-02-25 → 2025-06-05100Traditional
K250592 ↗NES Reprocessed Visions PV .018 Digital IVUS Catheter (R-86700)2025-02-27 → 2025-05-1274Traditional
K243101 ↗Medline ReNewal Reprocessed Siemens ACUSON AcuNav 10F Ultrasound Catheter (for Siemens Systems) (08255790 ); Medline ReNewal Reprocessed Siemens ACUSON AcuNav 10F Ultrasound Catheter (for GE Systems) (10043342)2024-09-30 → 2025-03-10161Traditional

Use this comparison: select a record to investigate, read its actual indications and design, and document differences. A shared code or elapsed period cannot establish its relevance to your device.

Calendar elapsed days are not active FDA review time, a promised schedule or a success probability. The selection includes only the stated recorded decisions, not all applications. Latest records can postdate the named historical decision and are contextual research, not its predicates. Shared codes, summaries and observed records do not prove equivalence, current market availability, buyer applicability or predicate suitability.

Calculation, selection and source versions

Reuse the complete-endpoint exact-primary-code, documented SE-decision cohort and its stated cutoff/window. Retain its type-7 quartiles only when at least 20 valid date pairs are present. Independently subtract the named official record’s receipt date from its decision date; missing or negative pairs remain unknown. Show up to four latest exact-code research records, excluding the named ID. Parent analysis hash, source snapshots and calculation versions are retained.

Calculation: fda-named-decision-cohort-context-1; cutoff 2026-09-27; 0 parent records excluded; units record counts; calendar elapsed days.

Source snapshots: 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002.

Read beyond the decision row

Recorded evidence and differences to investigate

The summary is manufacturer-submitted context hosted by FDA. Negative/no-study statements are preserved. Evidence themes are not binding legal requirements.

Short opening excerpts identify the source sections. Read the linked original for the full study context, negative statements, tables and limitations. Public quotations are limited to 120 words per acquired summary; the internal evidence packet retains exact section ranges for review.

Indications and users

K182238 · PDF page 4 ↗ Source 2

The  Reprocessed   ViewFlex™                   Xtra ICE  Catheter  is       indicated  for    use    in     adult and     adolescent pediatric   patients to  visualize
cardiac structures,    blood  flow   and   other devices  within the  heart.

Compare with your product: Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

Design and operating principle

K182238 · PDF page 5 ↗ Source 3

The Reprocessed ViewFlex Xtra ICE Catheter is a temporary intracardiac ultrasound catheter
 intended for use in patients to visualize cardiac structures and blood flow within the heart.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

Recorded comparison and differences

K182238 · PDF page 6 ↗ Source 4

The design, materials, and intended use of Reprocessed ViewFlex Xtra ICE Catheter are
equivalent to the predicate device.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: The summary’s comparison is a manufacturer statement about that submission. Investigate the actual design differences and cited records before considering any comparator or predicate.

Performance evidence actually described

K182238 · PDF page 6 ↗ Source 4

Bench and laboratory testing was conducted to demonstrate performance (safety and
effectiveness) of Reprocessed ViewFlex Xtra ICE Catheter.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

Extraction selection and limits

Select observed whole-line section headings or explicit colon-delimited inline labels on readable PDF pages, including the explicitly documented heading-spacing variants in this parser version. Preserve the original heading, character ranges and layout; do not repair excerpt text. Exclude letter boilerplate and uncertain pages. Stop at observed table headings; do not infer table columns or scalar results from layout text. Multi-column or suspicious split-numeric excerpts are excluded until reviewed alternate extraction is available. Original layout records remain retained; any alternate text has its own extractor-version locator and requires original-page review. For each dimension, prefer usable versioned alternate text where available, selecting its longest usable excerpt; otherwise select the longest usable original-layout excerpt. Ties preserve source order. Bounded to 64 PDF pages and 3,500 characters per section. This is a selection, not a complete dossier analysis.

Excluded extraction items: {}.

Known facts and deciding inputs

Known context: US. Confirm the organisation’s role, relevant activities and markets against the cited criteria.

Source factRecorded valueWhat to check
510(k) identifierK182238 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Generic device categoryReprocessed ViewFlex Xtra ICE Catheter [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded applicantStryker Sustainability Solutions [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
FDA product codeOWQ [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Decision date2019-05-08 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded decision codeSESE [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Submission typeTraditional [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Receipt date2018-08-20 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.

Prepare a differences and evidence worksheet

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Indications and users — what differs in our product?

    Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

    Useful evidence: Our proposed indication, user/population and use environment beside this exact recorded indication.

  2. Design and operating principle — what differs in our product?

    Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

    Useful evidence: Design description, materials/components, accessory list and a differences matrix.

  3. Recorded comparison and differences — what differs in our product?

    The summary’s comparison is a manufacturer statement about that submission. Investigate the actual design differences and cited records before considering any comparator or predicate.

    Useful evidence: Feature-by-feature differences and the underlying cited documents; no automated predicate selection.

  4. Performance evidence actually described — what differs in our product?

    The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

    Useful evidence: The cited narrative and full tables, underlying protocols/results and a reviewed comparison with the proposed product.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — 510(k) decision records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002

  • [1] device-510k-0001-of-0001.json:results[148434] · record ed9d1739829523a59d14672dfa6b9eec1485bbbf3ef9530916ccd6aa7de9175d
  • [5] Complete results array / fda-decision-context:K182238 · record whole dataset partition

FDA 510(k) summary — K182238 ↗

Mon, 10 Jun 2019 11:55:01 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 2f5351e16b8a4c2beb584c9adf3fb566b091977eac35948f6975ce7d2f94ff4c

  • [2] PDF page 4 · record b0d7083c0d778f3277b288b5db14c006fb74a4400b4a2830c860c4aa178e3881
  • [3] PDF page 5 · record 67c5461fb70c022799b06b28e38a9a9fab547aa0e63b042238bf7cdfe3545399
  • [4] PDF page 6 · record ff8da7c2497a91577c2588829520c5d7e005d6ef5634c3dee51eb69744fe6b24

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services