Recorded device evidence

BD BACTEC Peds Plus/F Culture Vials (plastic) (K151866): indications, design and recorded evidence

The acquired K151866 file contains product-specific indications and users, design and operating principle, performance evidence actually described sections. Compare these dated manufacturer statements with your own indication and design before commissioning evidence work. They describe this submission; they do not prescribe your testing, validate performance independently or establish a suitable predicate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Computed exact-code research

This decision beside its recorded product-code cohort

The 2021–2025 complete-year cohort contains 2 selected decisions under primary code MDB. 2 have valid reported receipt/decision pairs; 0 pairs are missing or invalid.

No quartiles are displayed: this complete-year cohort has fewer than 20 valid pairs.

The table shows the named decision and up to four latest exact-code research records through 2026-09-27. It can include partial-year records outside the complete-year cohort. The quartiles above use the full stated cohort, not this displayed selection.

Research recordRecorded deviceReceipt → decisionCalendar elapsed daysRecorded submission type
K151866 ↗ · this pageBD BACTEC Peds Plus/F Culture Vials (plastic)2015-07-09 → 2016-02-25231Traditional
K260213 ↗BD BACTEC FXI Culture System2026-01-23 → 2026-05-28125Traditional
K222591 ↗BD BACTEC™ Plus Aerobic/F Culture Vials2022-08-26 → 2023-03-24210Special
K222559 ↗BD BACTEC™ Myco/F Lytic Culture Vials2022-08-24 → 2023-03-24212Traditional
K190405 ↗BACT/ALERT MP Reagent System2019-02-19 → 2019-05-1585Traditional

Use this comparison: select a record to investigate, read its actual indications and design, and document differences. A shared code or elapsed period cannot establish its relevance to your device.

Calendar elapsed days are not active FDA review time, a promised schedule or a success probability. The selection includes only the stated recorded decisions, not all applications. Latest records can postdate the named historical decision and are contextual research, not its predicates. Shared codes, summaries and observed records do not prove equivalence, current market availability, buyer applicability or predicate suitability.

Calculation, selection and source versions

Reuse the complete-endpoint exact-primary-code, documented SE-decision cohort and its stated cutoff/window. Retain its type-7 quartiles only when at least 20 valid date pairs are present. Independently subtract the named official record’s receipt date from its decision date; missing or negative pairs remain unknown. Show up to four latest exact-code research records, excluding the named ID. Parent analysis hash, source snapshots and calculation versions are retained.

Calculation: fda-named-decision-cohort-context-1; cutoff 2026-09-27; 0 parent records excluded; units record counts; calendar elapsed days.

Source snapshots: 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002.

Read beyond the decision row

Recorded evidence and differences to investigate

The summary is manufacturer-submitted context hosted by FDA. Negative/no-study statements are preserved. Evidence themes are not binding legal requirements.

Short opening excerpts identify the source sections. Read the linked original for the full study context, negative statements, tables and limitations. Public quotations are limited to 120 words per acquired summary; the internal evidence packet retains exact section ranges for review.

Indications and users

K151866 · PDF page 3 ↗ Source 2

BD BACTEC Peds Plus™ /F Culture Vials (enriched Soybean-Casein Digest broth with CO2) are for aerobic blood cultures.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

Design and operating principle

K151866 · PDF page 4 ↗ Source 3

The sample to be tested is inoculated into one or more vials which are inserted into the BD
 BACTEC fluorescent series instrument for incubation and periodic reading.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

Performance evidence actually described

K151866 · PDF page 7 ↗ Source 4

Analytical Studies:

 Instrument Time to Detection
            A total of 473 paired sets were positive in both the modified and predicate devices. The Wilcoxon
 estimated median TTD difference for the 473positive sets is -0.250 hours (15 minutes), favoring the
 modified device.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

Extraction selection and limits

Select observed whole-line section headings or explicit colon-delimited inline labels on readable PDF pages, including the explicitly documented heading-spacing variants in this parser version. Preserve the original heading, character ranges and layout; do not repair excerpt text. Exclude letter boilerplate and uncertain pages. Stop at observed table headings; do not infer table columns or scalar results from layout text. Multi-column or suspicious split-numeric excerpts are excluded until reviewed alternate extraction is available. Original layout records remain retained; any alternate text has its own extractor-version locator and requires original-page review. For each dimension, prefer usable versioned alternate text where available, selecting its longest usable excerpt; otherwise select the longest usable original-layout excerpt. Ties preserve source order. Bounded to 64 PDF pages and 3,500 characters per section. This is a selection, not a complete dossier analysis.

Excluded extraction items: {}.

Known facts and deciding inputs

Known context: US. Confirm the organisation’s role, relevant activities and markets against the cited criteria.

Source factRecorded valueWhat to check
510(k) identifierK151866 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Generic device categoryBD BACTEC Peds Plus/F Culture Vials (plastic) [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded applicantBecton, Dickinson and Company [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
FDA product codeMDB [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Decision date2016-02-25 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded decision codeSESE [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Submission typeTraditional [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Receipt date2015-07-09 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.

Prepare a differences and evidence worksheet

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Indications and users — what differs in our product?

    Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

    Useful evidence: Our proposed indication, user/population and use environment beside this exact recorded indication.

  2. Design and operating principle — what differs in our product?

    Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

    Useful evidence: Design description, materials/components, accessory list and a differences matrix.

  3. Performance evidence actually described — what differs in our product?

    The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

    Useful evidence: The cited narrative and full tables, underlying protocols/results and a reviewed comparison with the proposed product.

Work packages and dependencies

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — 510(k) decision records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002

  • [1] device-510k-0001-of-0001.json:results[101490] · record 2881d9395e2d736afb6e187b07ed44329b783ebdaee68d83c67aa6a2539c3405
  • [5] Complete results array / fda-decision-context:K151866 · record whole dataset partition

FDA 510(k) summary — K151866 ↗

Tue, 05 Apr 2016 14:52:58 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 98cb73c63aaa78a91dd191c9e38b6ccef03e944069d00f0f31697c5bc757bb9d

  • [2] PDF page 3 · record 45d2e993719b32df3d0fdf8a3ab4c87272d17853bd1b4684e5ca5215083acebc
  • [3] PDF page 4 · record 07d9444f8b8a7b206f990143bbf05252bdc22f1878357dcec192b32e6a2e5918
  • [4] PDF page 7 · record 554ba0e8fe30560f2ce54d26904e734c0b2cda0cc6c665a82a6663c87e96daa5

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services