Recorded device evidence

NEOTRACT UROLIFT SYSTEM (K133281): indications, design and recorded evidence

The acquired K133281 file contains product-specific indications and users, design and operating principle, performance evidence actually described sections. Compare these dated manufacturer statements with your own indication and design before commissioning evidence work. They describe this submission; they do not prescribe your testing, validate performance independently or establish a suitable predicate.

Evidence retrieved 2026-10-07. Source versions and topic-specific limits are listed below.

Computed exact-code research

This decision beside its recorded product-code cohort

The 2021–2025 complete-year cohort contains 1 selected decisions under primary code PEW. 1 have valid reported receipt/decision pairs; 0 pairs are missing or invalid.

No quartiles are displayed: this complete-year cohort has fewer than 20 valid pairs.

The table shows the named decision and up to four latest exact-code research records through 2026-09-27. It can include partial-year records outside the complete-year cohort. The quartiles above use the full stated cohort, not this displayed selection.

Research recordRecorded deviceReceipt → decisionCalendar elapsed daysRecorded submission type
K133281 ↗ · this pageNEOTRACT UROLIFT SYSTEM2013-10-25 → 2013-12-2056Special
K232558 ↗UroLift 2 ATC Advanced Tissue Control System2023-08-23 → 2023-09-2230Special
K201837 ↗UroLift 2 System (formerly UL500), UroLift 2 Delivery Handle, UroLift 2 Implant Cartridge2020-07-02 → 2020-07-3129Special
K200441 ↗UroLift Advanced Tissue Control (ATC) System2020-02-24 → 2020-06-05102Traditional
K193269 ↗UroLift System (UL400)2019-11-26 → 2019-12-2024Special

Use this comparison: select a record to investigate, read its actual indications and design, and document differences. A shared code or elapsed period cannot establish its relevance to your device.

Calendar elapsed days are not active FDA review time, a promised schedule or a success probability. The selection includes only the stated recorded decisions, not all applications. Latest records can postdate the named historical decision and are contextual research, not its predicates. Shared codes, summaries and observed records do not prove equivalence, current market availability, buyer applicability or predicate suitability.

Calculation, selection and source versions

Reuse the complete-endpoint exact-primary-code, documented SE-decision cohort and its stated cutoff/window. Retain its type-7 quartiles only when at least 20 valid date pairs are present. Independently subtract the named official record’s receipt date from its decision date; missing or negative pairs remain unknown. Show up to four latest exact-code research records, excluding the named ID. Parent analysis hash, source snapshots and calculation versions are retained.

Calculation: fda-named-decision-cohort-context-1; cutoff 2026-09-27; 1 parent records excluded; units record counts; calendar elapsed days.

Source snapshots: 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002.

Read beyond the decision row

Recorded evidence and differences to investigate

The summary is manufacturer-submitted context hosted by FDA. Negative/no-study statements are preserved. Evidence themes are not binding legal requirements.

Short opening excerpts identify the source sections. Read the linked original for the full study context, negative statements, tables and limitations. Public quotations are limited to 120 words per acquired summary; the internal evidence packet retains exact section ranges for review.

Indications and users

K133281 · PDF page 1 ↗ Source 2

The        UroLift          System        is intended        for   the       treatment        of   symptoms        due   to          urinary         outflow     obstruction
secondary           to        benign        prostatic       hyperplasia           (BPH)           in men         50   years        of   age        or     older.

Compare with your product: Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

Design and operating principle

K133281 · PDF page 1 ↗ Source 2

The        NeoTract          UroLift          System         comprises         two      main       components,            the        UroLift      Delivery          Device        and
UroLift         Implant.                   Each        delivery           device          comes      pre-loaded            with        one     UroLift          Implant.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

Performance evidence actually described

K133281 · PDF page 2 ↗ Source 3

Transit          and       functionality             testing     conducted           on       the      modified        NeoTract              UroLift      System
demonstrate           that       the      device          meets          the     same        performance             requirements            as      the        unmodified
predicate          device.

The excerpt is shortened at a complete statement. Read the complete section in the original PDF before interpreting the evidence.

Compare with your product: The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

Extraction selection and limits

Select observed whole-line section headings or explicit colon-delimited inline labels on readable PDF pages, including the explicitly documented heading-spacing variants in this parser version. Preserve the original heading, character ranges and layout; do not repair excerpt text. Exclude letter boilerplate and uncertain pages. Stop at observed table headings; do not infer table columns or scalar results from layout text. Multi-column or suspicious split-numeric excerpts are excluded until reviewed alternate extraction is available. Original layout records remain retained; any alternate text has its own extractor-version locator and requires original-page review. For each dimension, prefer usable versioned alternate text where available, selecting its longest usable excerpt; otherwise select the longest usable original-layout excerpt. Ties preserve source order. Bounded to 64 PDF pages and 3,500 characters per section. This is a selection, not a complete dossier analysis.

Excluded extraction items: {}.

Known facts and deciding inputs

Known context: US. Confirm the organisation’s role, relevant activities and markets against the cited criteria.

Source factRecorded valueWhat to check
510(k) identifierK133281 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Generic device categoryNEOTRACT UROLIFT SYSTEM [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded applicantNeotract, Inc. [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
FDA product codePEW [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Decision date2013-12-20 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Recorded decision codeSESE [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Submission typeSpecial [1]Dated official record fact; not proof of current commercial availability or applicability to another device.
Receipt date2013-10-25 [1]Dated official record fact; not proof of current commercial availability or applicability to another device.

Prepare a differences and evidence worksheet

Use this checklist to gather your business or product details before speaking with a specialist. The items below explain what to record and suggest useful supporting documents. You can add your own answers in the editable project brief.

  1. Indications and users — what differs in our product?

    Compare the recorded indication, population, body site and use environment with your proposed label. Record each change instead of assuming the primary code settles intended use.

    Useful evidence: Our proposed indication, user/population and use environment beside this exact recorded indication.

  2. Design and operating principle — what differs in our product?

    Compare physical design, materials, energy, accessories and operating principle with your design. Ask which documented differences change the evidence scope.

    Useful evidence: Design description, materials/components, accessory list and a differences matrix.

  3. Performance evidence actually described — what differs in our product?

    The source labels this section as performance data. Determine which described evidence is bench, software, biological or clinical from the actual narrative and original tables; the section label alone does not settle that distinction or prescribe your testing.

    Useful evidence: The cited narrative and full tables, underlying protocols/results and a reviewed comparison with the proposed product.

Work packages and dependencies

What needs to happen first

Questions for providers

Sources and data dates

Read the official document in context. The audit details identify the precise locators and preserved versions used for this page.

FDA openFDA — 510(k) decision records ↗

2026-10-05 · retrieved 2026-10-06

Audit details: precise locators and snapshot identifiers

Source key D01 · snapshot 5a86994ba49a37e71e09be96803fd51981c6c43eaa96caab41aea2b188bfe002

  • [1] device-510k-0001-of-0001.json:results[47952] · record 3c9a463474c5ecb7492cc776c6a22107e184f439acec1cbbc361c594f94bc1ae
  • [4] Complete results array / fda-decision-context:K133281 · record whole dataset partition

FDA 510(k) summary — K133281 ↗

Tue, 14 Jan 2014 13:01:41 GMT · retrieved 2026-10-07

Audit details: precise locators and snapshot identifiers

Source key D02 · snapshot 660d44e4dc9cd92eb5213862a2d647c2694ecaadb37c1f0a060ba8b70e1e049a

  • [2] PDF page 1 · record 0942b077e6efa6cabb5cec24a5665d33f9d651e4399c95705da234e96f492c61
  • [3] PDF page 2 · record 94810bb8282aa248e7e3b1cd4f1adadb692d9a4bc9ef02688fcbb742d7a46fd9

Prepare an editable project brief

Confirm the facts, scope and contact preference before sharing your project. Preparing this page sends no provider outreach.

Choose work packages to discuss

Compare FDA 510(k) Submission Services

Usability / Human Factors Testing